Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: C.C. BUILDS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C.C. BUILDS in NEAR INTERSECTION OF OLD TOWN HALL RD AND GRAFF RD, EAU CLAIRE, WI 54701 (NAICS 238130). OSHA activity number 346193493.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C.C. Builds — free Get an email when a new federal OSHA severe-injury report for C.C. Builds is published. One employer, no account, unsubscribe in one click.
Establishment
C.C. BUILDS
Site address
NEAR INTERSECTION OF OLD TOWN HALL RD AND GRAFF RD
City
EAU CLAIRE
State
WI
ZIP
54701
Mailing
101 NORTH HILL STREET, FAIRCHILD, WI 54741
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 30, 2022
Abate by
Jan 17, 2023
Penalty
Initial $4,786 · Current $2,000 Reduced
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   (a) Residential structure; One or more methods of fall protection was not in place while a worker performed sheathing work on a residential roof at heights greater than 18 feet above ground level.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4786

1926.503 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 30, 2022
Abate by
May 1, 2023
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  (a) Residential structure; A worker exposed to fall hazards associated with residential sheathing was not adequately trained to recognize fall hazards and/or the procedures to be followed to minimize fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1052 C01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 30, 2022
Abate by
Jan 17, 2023
Penalty
Initial $2,735 · Current $500 Reduced
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:  (a) Interior stairways to the upper floor level; Stairways comprised of four or more risers and rising more than approximately 63 inches were not equipped with at least one handrail and were used by workers to access the upper floor level.
Recent events (2)
  • — I (S) $500
  • — Z (S) $2735

1926.1052 C01 II

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Dec 30, 2022
Abate by
Jan 17, 2023
Penalty
Initial $0 · Current $0
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:  (a) Interior stairways to the upper floor level; Stairways used to access the upper floor level were comprised of four or more risers and were not equipped with a stairrail system along each unprotected side or edge.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L06

Other-than-serious 1 instance 1 exposed
Issued
Dec 30, 2022
Abate by
May 1, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6):  The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l) and as referenced by the note contained in 1926.602(d):   (a) Building exterior; A certification of operator evaluation was not maintained for a worker who operated a JLG Gradall rough-terrain forklift (Model No. G6-42A).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View C.C. Builds's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346193493.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.