DALLAS, TX —
OSHA Inspection: DALLAS MFG (GTS, HTAS)
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DALLAS MFG (GTS, HTAS) in 12828 VALLEY BRANCH LN., DALLAS, TX 75234 (NAICS 332216). OSHA activity number 346201734.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DALLAS MFG (GTS, HTAS)
- Site address
- 12828 VALLEY BRANCH LN.
- City
- DALLAS
- State
- TX
- ZIP
- 75234
- Mailing
- 12828 VALLEY BRANCH LN., DALLAS, TX 75234
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332216
- Employees
- 320
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.22 D02
- Issued
- Dec 15, 2022
- Abate by
- Dec 28, 2022
- Penalty
- Initial $14,502 · Current $14,502
General-duty citation text
29 CFR 1910.22(d)(2): Hazardous conditions on walking-working surfaces were not corrected or repaired before an employee used the walking-working surface. If the correction or repair cannot be made immediately, the hazard must be guarded to prevent employees from using the walking-working surface until the hazard was corrected or repaired: a) On or about September 6, 2022, and at times prior thereto; in the Hammer Forge department, where employees were not protected from a slipping hazard while working and walking on the slippery floor that was not repaired or guarded.
Recent events (2)
- — C (S) $14502
- — Z (S) $14502
1910.218 B02
- Issued
- Dec 15, 2022
- Abate by
- Dec 28, 2022
- Penalty
- Initial $14,502 · Current $14,502
General-duty citation text
29 CFR 1910.218(b)(2): All foot operated devices (i.e., treadles, pedals, bars, valves, and switches) were not substantially and effectively protected from unintended operation. On or about September 6, 2022, and at times prior thereto; in the Hammer Forge department, where foot operated pedals were not substantially and effectively protected from unintended operation. a. Foot operated pedal to control the Chambersburg Die Forger #14. b. Foot operated pedal to control the Trim press machine.
Recent events (2)
- — C (S) $14502
- — Z (S) $14502
1910.303 E01 II
- Issued
- Dec 15, 2022
- Abate by
- Dec 28, 2022
- Penalty
- Initial $10,360 · Current $10,360
General-duty citation text
29 CFR 1910.303(e)(1)(ii): Electric equipment was used without markings giving voltage, current, wattage, or other ratings as necessary: a) On or about September 7, 2022, and at times prior thereto; the electrical panel DPA- 1A used to power the electrical box for welder and other equipment was not markings giving voltage, current, or other ratings as necessary. b) On or about September 7, 2022, and at times prior thereto; the disconnect to power die heater was not markings giving voltage, current, or other ratings as necessary.
Recent events (2)
- — C (S) $10360
- — Z (S) $10360
1910.303 F02
- Issued
- Dec 15, 2022
- Abate by
- Dec 28, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) This violation occurred on or about September 7, 2022, and at times prior thereto; In Hammer Forge department, where circuit breaker panel DPA-1A was not marked to indicate the purpose of individual breakers.
Recent events (2)
- — C (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Dec 15, 2022
- Penalty
- Initial $10,360 · Current $10,360
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) The employer did not close opening on electrical equipment. This violation occurred on or about September 7, 2022, in the Hammer Forge department, where a metal electrical box of 480 Volts used to power welder and other equipment had opening at the right side of the box.
Recent events (2)
- — C (S) $10360
- — Z (S) $10360
More inspections in this industry (NAICS 332216)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346201734.