Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: CARBONE MASONRY AND RESTORATION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CARBONE MASONRY AND RESTORATION LLC in 1912-14 BERLIN TURNPIKE, WETHERSFIELD, CT 06109 (NAICS 238140). OSHA activity number 346202385.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Carbone Masonry and Restoration LLC for free Get an email when a new federal OSHA severe-injury report for Carbone Masonry and Restoration LLC is published. One employer, no account, unsubscribe in one click.
Site address
1912-14 BERLIN TURNPIKE
City
WETHERSFIELD
State
CT
ZIP
06109
Mailing
326 GRISWOLD ROAD, WETHERSFIELD, CT 06109
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
6
Ownership type
Private (A)

4 citations on file for this inspection.

1926.300 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 3, 2023
Penalty
Initial $2,486 · Current $2,000 Reduced
29 CFR  1926.300(b)(1):Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:  On or about September 7, 2022, an employee was using a powered hand grinder to grind off burrs and rust from angle iron and the guard was not in use.
Recent events (2)
  • · I (S) $2000
  • · Z (S) $2486

1926.404 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 3, 2023
Penalty
Initial $3,108 · Current $2,000 Reduced
29 CFR  1926.404(b)(1)(ii):On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection.  On or about September 7, 2022, an employee was using a electrically powered hand grinder to grind off burrs and rust from pieces of angle iron and the grinder was energized and in use without any GFCI protection.
Recent events (2)
  • · I (S) $2000
  • · Z (S) $3108

1926.405 G02 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 3, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.405(g)(2)(iv):Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  On or about September 7, 2022, an employee was using a electrically powered hand grinder to grind off burrs and rust from pieces of angle iron and the extension cord in use had strain relief damage.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.701 B

Serious Gravity 5 1 instance 6 exposed
Issued
Jan 3, 2023
Penalty
Initial $3,108 · Current $2,000 Reduced
29 CFR  1926.701(b):All protruding reinforcing steel, onto and/or into which employees could fall, was not guarded to eliminate the hazard of impalement:  On or about September 7, 2022, employees including the foreman were working at and near unguarded rebar.
Recent events (2)
  • · I (S) $2000
  • · Z (S) $3108

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 346202385.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.