Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALL SEASONS ROOFING LLC

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of ALL SEASONS ROOFING LLC in 1156 CURRY ROAD, ROTTERDAM, NY 12306 (NAICS 238160). OSHA activity number 346202732.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ALL Seasons Roofing LLC — free Get an email when a new federal OSHA severe-injury report for ALL Seasons Roofing LLC is published. One employer, no account, unsubscribe in one click.
Site address
1156 CURRY ROAD
City
ROTTERDAM
State
NY
ZIP
12306
Mailing
1105 JERRY AVE, ROTTERDAM, NY 12306
Inspection type
Programmed Related (J)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 3 instances 3 exposed
Issued
Jan 25, 2023
Abate by
Feb 6, 2023
Penalty
Initial $2,679 · Current $1,741 Reduced
29 CFR  1926.102(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  (a) During roofing work:   On or prior to 9/08/22, employees were not wearing protective eyewear while prepping the roof for installation of roof shingles.
Recent events (2)
  • — I (S) $1741.35
  • — Z (S) $2679

1926.501 B11

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 25, 2023
Penalty
Initial $3,349 · Current $2,177 Reduced
29 CFR  1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  (a ) Roof of building, during  prep for installation of asphalt shingles:  On or prior to 7/27/22, employees were performing roofing work along the edges of the roof approximately 8 feet above the ground; no fall protection system was in use.
Recent events (2)
  • — I (S) $2176.85
  • — Z (S) $3349

1926.503 A01

Serious Gravity 1 1 instance 3 exposed
Issued
Jan 25, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards:   (a ) Roof of building, during prep for installation of asphalt shingles:  On or prior to 9/08/22, employees were performing roofing work along the roof of a residential building and was not provided with training in the recognition and avoidance of fall hazards associated with roofing work on a steep roof, including use of personal fall arrest system(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.404 B01 II

Other-than-serious 1 instance 3 exposed
Issued
Jan 25, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection.  (a) During roofing work:   On or prior to 9/08/22, two extension cords in use were not provided with GFCI protection, exposing employees to shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.1053 B05 I

Other-than-serious 1 instance 3 exposed
Issued
Jan 25, 2023
Abate by
Feb 6, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder:  (a) During roofing work:  On or prior to 9/08/22, fiberglass extension ladder  on the east side of the roof was used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately 3/4 the working length of the ladder (45-50 degrees).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View ALL Seasons Roofing LLC's full OSHA safety record →