Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KINGS ISLAND PARK LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of KINGS ISLAND PARK LLC in 6300 KINGS ISLAND DRIVE, MASON, OH 45040 (NAICS 713110). OSHA activity number 346209232.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kings Island Park LLC — free Get an email when a new federal OSHA severe-injury report for Kings Island Park LLC is published. One employer, no account, unsubscribe in one click.
Site address
6300 KINGS ISLAND DRIVE
City
MASON
State
OH
ZIP
45040
Mailing
P. O. BOX 901 6300 KINGS ISLAND DRIVE, KINGS ISLAND, OH 45034
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713110
Employees
500
Ownership type
A

9 citations on file for this inspection.

1910.107 B09

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 4, 2023
Abate by
Feb 8, 2023
Penalty
Initial $5,594 · Current $1,833 Reduced
29 CFR  1910.107(b)(9): Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.  a.) On or about December 5, 2022, the employer did not have 3 feet of space on all side of the spray booth free from storage in that equipment such as, but not limited to a work bench made of wood, a flammable liquid storage cabinet, and paint gun washer station containing flammable liquid were stored against the outside wall of the spray booth.
Recent events (2)
  • — I (S) $1833.35
  • — Z (S) $5594

1910.134 F02

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 4, 2023
Abate by
Jan 24, 2023
Penalty
Initial $5,594 · Current $1,833 Reduced
29 CFR  1910.134(f)(2): The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter.  a.) On or about December 5, 2022, the employer did not provide an annual fit test to employees required to wear 3M 6300 half mask elastomeric respirator when spraying paint inside the paint booth.
Recent events (2)
  • — I (S) $1833.33
  • — Z (S) $5594

1910.134 F05

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 4, 2023
Abate by
Jan 24, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.134(f)(5): The fit test shall be administered using an OSHA-accepted QLFT or QNFT protocol. The OSHA-accepted QLFT and QNFT protocols and procedures are contained in Appendix A of this section.  a.) On or about December 5, 2022, the employer did not ensure employees required to wear a 3M 6300 half mask elastomeric respirator when spraying paint in the paint booth were clean shaven and did not have facial hair between the sealing surface of the facepiece when administering a qualitative fit test.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 G01 I A

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 4, 2023
Abate by
Jan 24, 2023
Penalty
Initial $0 · Current $0
1910.134(g)(1)(i): The employer shall not permit respirators with tight-fitting facepieces to be worn by employees who have: Facial hair that comes between the sealing surface of the facepiece and the face or that interferes with valve function;  a.) On or about December 5, 2022, the employer did not ensure employees required to wear a 3M 6300 half mask elastomeric respirator when spraying paint in the paint booth were clean shaven and did not have facial hair between the sealing surface of the facepiece.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 4, 2023
Abate by
Jan 24, 2023
Penalty
Initial $9,324 · Current $1,833 Reduced
29 CFR  1910.178(a)(4): Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly.  a) On or about September 12, 2022, the employer did not obtain the manufacturers prior written approval when the boom attachment, used to set up the fa�ade at the main entrance, was added to the JLG 610-55A.
Recent events (2)
  • — I (S) $1833.33
  • — Z (S) $9324

1910.212 A01

Serious Gravity 5 3 instances 2 exposed
Issued
Jan 4, 2023
Abate by
Jan 24, 2023
Penalty
Initial $9,324 · Current $1,833 Reduced
29 CFR  1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.  a.) On or about August 8, 2022, the employer did not ensure that the Sears, Roebuck and Co Model 113.21371 15.5" Drill Press, located in Mech 5, had a guard over the chuck and the drill bit used to drill out pilot holes for a broken bracket.  b.) On or about December 2, 2022, the employer did not ensure that the Enerpac 100-ton Hydraulic Press, located in Mech 1, was adequately guarded in that employees are exposed to hazards at the point of operation, such as pinch points and amputation, due to employees being able to remove the plexi-glass guard.
Recent events (2)
  • — I (S) $1833.33
  • — Z (S) $9324

1910.253 B02 II

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Jan 4, 2023
Penalty
Initial $9,324 · Current $1,833 Reduced
29 CFR  1910.253(b)(2)(ii): Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards.  a) On September 7, 2022, the employer did not ensure that the Food Grade Carbon Dioxide cylinder was not secure from being knocked over by employees entering the back storage and dish storage area of the International Restaurant.
Recent events (2)
  • — I (O) $1833.33
  • — Z (S) $9324

1910.303 B02

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Jan 4, 2023
Abate by
Feb 8, 2023
Penalty
Initial $9,324 · Current $1,833 Reduced
29 CFR  1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.  a) On or about September 8, 2022, the employer did not ensure flexible extension cords were used in accordance with the manufacturer's instructions.  Flexible extension cords were  connected together to supply power to two exhaust fans and the Rain Bird sprinkler system control panel.
Recent events (2)
  • — I (O) $1833.33
  • — Z (S) $9324

1910.305 G01 IV A

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Jan 4, 2023
Abate by
Feb 8, 2023
Penalty
Initial $9,324 · Current $0 Reduced
29 CFR  1910.305(g)(1)(iv): Use of flexible cords and cables.  Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used: As a substitute for the fixed wiring of a structure;  a) On or about September 8, 2022, the employer did not ensure flexible extension cords were not used as fixed wiring in the greenhouse to supply power to two exhaust fans and the Rain Bird sprinkler system control panel.
Recent events (2)
  • — I (O) $0
  • — Z (S) $9324

View Kings Island Park LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346209232.