Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INTERMOUNTAIN ELECTRONICS, INC. OF PRICE UTAH

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of INTERMOUNTAIN ELECTRONICS, INC. OF PRICE UTAH in 400 SWAN AVE, CENTRALIA, IL 62801 (NAICS 335999). OSHA activity number 346217938.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Intermountain Electronics, INC. of Price Utah — free Get an email when a new federal OSHA severe-injury report for Intermountain Electronics, INC. of Price Utah is published. One employer, no account, unsubscribe in one click.
Site address
400 SWAN AVE
City
CENTRALIA
State
IL
ZIP
62801
Mailing
400 SWAN AVE, CENTRALIA, IL 62801
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335999
Employees
46
Ownership type
A

2 citations on file for this inspection.

1926.307 F03

Serious Gravity 5 1 instance 5 exposed
Issued
Feb 8, 2023
Penalty
Initial $7,813 · Current $4,297 Reduced
29 CFR  1926.307(f)(3):The employer failed to guard gears, sprockets and/or chains that were less than 7 feet (2.128 m) from the floor or platform:  On and before September 14, 2022, employees were exposed to nip point hazard created by unguarded sprockets that were approximately 5 feet from the floor.
Recent events (2)
  • — I (S) $4297
  • — Z (S) $7813

1926.754 A

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 8, 2023
Penalty
Initial $15,625 · Current $8,594 Reduced
29 CFR  1926.754(a):Structural stability was not maintained at all times during the erection process:   On and about September 14, 2022, employees were exposed to a wall collapse of Kingspan K-Roc Series Wall Panels that were erected together and structural stability was not maintained at all times.
Recent events (2)
  • — I (S) $8594
  • — Z (S) $15625

View Intermountain Electronics, INC. of Price Utah's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346217938.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.