SAVANNAH, GA —
OSHA Inspection: DAMARI LOPEZ PEREZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DAMARI LOPEZ PEREZ in 25 RED ROBIN CT, SAVANNAH, GA 31407 (NAICS 238160). OSHA activity number 346222763.
Where did this inspection happen?
- Establishment
- DAMARI LOPEZ PEREZ
- Site address
- 25 RED ROBIN CT
- City
- SAVANNAH
- State
- GA
- ZIP
- 31407
- Mailing
- 321 SANDER RD, HARDEEVILLE, SC 29927
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $4351.00 · Current $4351.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At 25 Red Robin Court, Savannah, GA 31407, on or about September 15, 2022, the employer exposed her employee to fall hazards greater than 10 feet, in that the employer allowed her employee to perform framing activities without using fall protection.
Recent events (1)
- — Z (S) $4351
1926.1053 B01
- Issued
- Penalty
- Initial $3108.00 · Current $3108.00
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) At 25 Red Robin Court, Savannah, GA 31407, on or about September 15, 2022, the employer exposed her employee to fall hazards greater than 10 feet, in that the extension ladder they used to gain access to the roof did not have the side rails of the ladder extended at least three feet above the landing to provide safe access to the roof.
Recent events (1)
- — Z (S) $3108
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in GA
GREENSBORO, GA—2026-07-16
PURE BEAUTY FARMS, INC.
FOREST PARK, GA—2026-07-16
POLYNT COMPOSITES USA INC.
AUGUSTA, GA—2026-07-16
GF CASTING SOLUTIONS AUGUSTA, LLC
CHAMBLEE, GA—2026-07-16
U.S. DEPARTMENT OF TREASURY
DECATUR, GA—2026-07-15
PALLETS ACQUISITION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346222763.