Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UR HOME SWEET HOME LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UR HOME SWEET HOME LLC in 727 WILSON AVE, ARCADIA, WI 54612 (NAICS 238130). OSHA activity number 346222813.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch UR Home Sweet Home LLC — free Get an email when a new federal OSHA severe-injury report for UR Home Sweet Home LLC is published. One employer, no account, unsubscribe in one click.
Site address
727 WILSON AVE
City
ARCADIA
State
WI
ZIP
54612
Mailing
PO BOX 55, STRUM, WI 54770
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 12, 2023
Abate by
Jan 27, 2023
Penalty
Initial $1,865 · Current $1,399 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  (a) Residential structure; A hardhat was not worn by a worker who was exposed to an overhead hazard of roofing panel(s) falling on him during roofing operations.
Recent events (2)
  • — I (S) $1398.75
  • — Z (S) $1865

1926.453 B02 V

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jan 12, 2023
Abate by
Jan 27, 2023
Penalty
Initial $2,486 · Current $0 Reduced
29 CFR  1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: Note:  As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system.  The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated under 1926.502(e):  (a) Building exterior; A worker in an elevated Snorkelift UNO41D aerial lift (Serial No. 207642) was not wearing a body belt or harness and was not attached to the boom or basket.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2486

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 12, 2023
Abate by
Jan 27, 2023
Penalty
Initial $3,729 · Current $2,797 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   (a) Residential structure; One or more methods of fall protection was not in place while workers performed roofing operations at heights greater than 13 feet above ground level.
Recent events (2)
  • — I (S) $2796.75
  • — Z (S) $3729

1926.1052 C01 I

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Jan 12, 2023
Abate by
Jan 27, 2023
Penalty
Initial $3,729 · Current $0 Reduced
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:  (a) Interior stairway to the upper floor level; A stairway comprised of more than four risers was not equipped with at least one handrail and was used by workers to access the upper floor level.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3729

1926.1052 C01 II

Other-than-serious Gravity 5 1 instance 5 exposed
Issued
Jan 12, 2023
Abate by
Jan 27, 2023
Penalty
Initial $0 · Current $1,865
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:   (a) Interior stairway to the upper floor level; A stairway used to access the upper floor level was comprised of more than four risers and was not equipped with a stairrail system along each unprotected side or edge.
Recent events (2)
  • — I (O) $1864.5
  • — Z (S) $0

1926.503 B01

Deleted Other-than-serious 1 instance 2 exposed
Issued
Jan 12, 2023
Abate by
Feb 3, 2023
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer:  (a) Residential structure; The employer did not provide a written certification record of fall protection training.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346222813.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.