SALEM, NH —
OSHA Inspection: Q. C. DRILLING/ROUTING SERVICE, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of Q. C. DRILLING/ROUTING SERVICE, INC. in 37 NORTHWESTERN DRIVE, SALEM, NH 03079 (NAICS 333249). OSHA activity number 346226251.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- Q. C. DRILLING/ROUTING SERVICE, INC.
- Site address
- 37 NORTHWESTERN DRIVE
- City
- SALEM
- State
- NH
- ZIP
- 03079
- Mailing
- 37 NORTHWESTERN DRIVE, SALEM, NH 03079
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333249
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 A02 II B
- Issued
- Mar 6, 2023
- Abate by
- Mar 23, 2023
- Penalty
- Initial $4,688 · Current $4,688
General-duty citation text
29 CFR 1910.147(a)(2)(ii)(B): (A) An employee was required to place a part of his or her body into an area on a machine or piece of equipment where an associated danger zone existed during a machine operating cycle: a. Site- On September 10, 2022 an employee was seriously injured when he was pinned inside of a Datron M10 Pro-C CNC machine that he was cleaning while the machine was operating.
Recent events (2)
- — I (S) $4688
- — Z (S) $4688
1910.147 C01
- Issued
- Mar 6, 2023
- Abate by
- Mar 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a. Site- The employer did not establish and maintain an energy control program for employees who perform routine maintenance work and cleaning on machinery.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Mar 6, 2023
- Abate by
- Mar 23, 2023
- Penalty
- Initial $4,688 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. Site- a. Site- Employees operating the Datron M10 Pro-C CNC machine were not protected from machine guarding hazards when the interlock mechanism on the machine door was altered in a manner which allowed the machine to operate with the doors open.
Recent events (2)
- — I (S) $0
- — Z (S) $4688