GLENDALE, WI —
OSHA Inspection: A.B. DATA, LTD.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of A.B. DATA, LTD. in 600 A B DATA DRIVE, GLENDALE, WI 53217 (NAICS 541613). OSHA activity number 346233190.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A.B. DATA, LTD.
- Site address
- 600 A B DATA DRIVE
- City
- GLENDALE
- State
- WI
- ZIP
- 53217
- Mailing
- 600 A B DATA DRIVE, GLENDALE, WI 53217
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541613
- Employees
- 126
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C01
- Issued
- Jan 13, 2023
- Abate by
- Feb 2, 2023
- Penalty
- Initial $11,094 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. (a) On or about September 14, 2022, the employer did not establish a program consisting of energy control procedures, employee training and periodic inspections, to ensure that before any employee performs servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury.
Recent events (2)
- — I (S) $5000
- — Z (S) $11094
1910.147 C04 I
- Issued
- Jan 13, 2023
- Abate by
- Feb 9, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or about September14, 2022, the employer did not ensure procedures were developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section, which includes maintenance and servicing of air handling units, light fixtures and electrical equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D
- Issued
- Jan 13, 2023
- Abate by
- Feb 9, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) On or about September 14, 2022, an employee performed maintenance and servicing work on the #7 HVAC unit without locking out the energy sources. This exposed the employee to a crushing and caught-in hazard. hazard. The employer failed to implement energy control application steps as the machine(s) were not isolated from all energy sources [per the 1910.147(d)(3) requirements]. As a result, the remaining applicable energy control elements, involving LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G02 I
- Issued
- Jan 13, 2023
- Abate by
- Jan 20, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): (a) On or about about September 14, 2022, a employee performed work on or around HVAC Unit #7, that had energized and exposed electrical wiring and equipment rated at 120 volts AC or greater. The exposed electrical equipment was an electrical box without a box cover, located on the right bottom side and below the HVAC unit access doors. This exposed employees to an electrical shock hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at A.B. Data, LTD.
View A.B. Data, LTD.'s full OSHA safety record →
More inspections in this industry (NAICS 541613)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346233190.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.