KETTERING, OH —
OSHA Inspection: A.C. AGUILAR ROOFING & SIDING OF GREATER DAYTON, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of A.C. AGUILAR ROOFING & SIDING OF GREATER DAYTON, LLC in 3251 REVLON DR., KETTERING, OH 45420 (NAICS 238160). OSHA activity number 346233901.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A.C. AGUILAR ROOFING & SIDING OF GREATER DAYTON, LLC
- Site address
- 3251 REVLON DR.
- City
- KETTERING
- State
- OH
- ZIP
- 45420
- Mailing
- 360 BLACKSTONE DR., DAYTON, OH 45459
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Nov 14, 2022
- Penalty
- Initial $4,351 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. A.) On September 20, 2022, employees were not utilizing any type of fall protection system while re-roofing a residential structure. The potential fall height was measured to be 7'-8" with a roof pitch of 4/12.
Recent events (2)
- — I (S) $1000
- — Z (S) $4351
1926.503 A01
- Issued
- Nov 14, 2022
- Abate by
- Jan 3, 2023
- Penalty
- Initial $4,351 · Current $0 Reduced
General-duty citation text
29 CFR 1926.503(a)(1):The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards. A.) On or about September 20, 2022, and prior to that date, employees were not trained in the recognition and avoidance of fall hazards in that they were re-roofing a residential structure while not utilizing any type of fall protection system.
Recent events (2)
- — I (S) $0
- — Z (S) $4351
1926.1053 B01
- Issued
- Nov 14, 2022
- Penalty
- Initial $4,351 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. A.) On September 20, 2022, the fiberglass extension ladder that was used to access the roof of a residential structure was not raised up at least 36" above the upper landing surface nor was there a separate hand hold installed which would give employees a hand hold while accessing and exiting the ladder at a height measured to be 7'-8" to the ground below.
Recent events (2)
- — I (S) $1000
- — Z (S) $4351