Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A.C. AGUILAR ROOFING & SIDING OF GREATER DAYTON, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of A.C. AGUILAR ROOFING & SIDING OF GREATER DAYTON, LLC in 3251 REVLON DR., KETTERING, OH 45420 (NAICS 238160). OSHA activity number 346233901.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A.C. Aguilar Roofing & Siding of Greater Dayton, LLC — free Get an email when a new federal OSHA severe-injury report for A.C. Aguilar Roofing & Siding of Greater Dayton, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3251 REVLON DR.
City
KETTERING
State
OH
ZIP
45420
Mailing
360 BLACKSTONE DR., DAYTON, OH 45459
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 14, 2022
Penalty
Initial $4,351 · Current $1,000 Reduced
29 CFR  1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  A.) On September 20, 2022, employees were not utilizing any type of fall protection system while re-roofing a residential structure. The potential fall height was measured to be 7'-8" with a roof pitch of 4/12.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $4351

1926.503 A01

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Nov 14, 2022
Abate by
Jan 3, 2023
Penalty
Initial $4,351 · Current $0 Reduced
29 CFR  1926.503(a)(1):The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards.  A.) On or about September 20, 2022, and prior to that date, employees were not trained in the recognition and avoidance of fall hazards in that they were re-roofing a residential structure while not utilizing any type of fall protection system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4351

1926.1053 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 14, 2022
Penalty
Initial $4,351 · Current $1,000 Reduced
29 CFR  1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  A.) On September 20, 2022, the fiberglass extension ladder that was used to access the roof of a residential structure was not raised up at least 36" above the upper landing surface nor was there a separate hand hold installed which would give employees a hand hold while accessing and exiting the ladder at a height measured to be 7'-8" to the ground below.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $4351

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346233901.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.