Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: R.F. KNOX COMPANY INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of R.F. KNOX COMPANY INC. in 4865 MARTIN COURT, SMYRNA, GA 30082 (NAICS 332996). OSHA activity number 346235989.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R.F. Knox Company INC. — free Get an email when a new federal OSHA severe-injury report for R.F. Knox Company INC. is published. One employer, no account, unsubscribe in one click.
Site address
4865 MARTIN COURT
City
SMYRNA
State
GA
ZIP
30082
Mailing
4865 MARTIN COURT, SMYRNA, GA 30082
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332996
Employees
159
Ownership type
A

2 citations on file for this inspection.

1910.95 G01

Serious Gravity 1 2 instances 2 exposed
Issued
Mar 8, 2023
Abate by
Apr 3, 2023
Penalty
Initial $4,068 · Current $2,441 Reduced
29 CFR  1910.95(g)(1):The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels:  a) Production Area:  An employee fabricating metal duct was exposed to 69.21% of the permissible daily exposure of 85 dBA (8-hour time weighted average) or an equivalent sound level of 87.3 dBA during the 443 minute sampling period on November 1, 2022. The exposure calculation included a zero increment for the 37 minutes not sampled. The employer has not provided the employee with audiometric testing.  b) Production Area:  An employee fabricating metal duct was exposed to 70.61% of the permissible daily exposure of 85 dBA (8-hour time weighted average) or an equivalent sound level of 87.5 dBA during the 446 minute sampling period on November 1, 2022. The exposure calculation included a zero increment for the 34 minutes not sampled. The employer has not provided the employee with audiometric testing.
Recent events (2)
  • — I (S) $2440.8
  • — Z (S) $4068

1910.252 B02 III

Serious Gravity 1 1 instance 20 exposed
Issued
Mar 8, 2023
Penalty
Initial $3,458 · Current $2,075 Reduced
29 CFR  1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:  a) Production Area: On or about September 21, 2022, and at times prior, the employer exposed employees to radiation hazards, in that an adequate number of protective welding screens were not provided and placed around welding stations to provide sufficient shielding from the welding arc flash for employees in the adjacent areas.