Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMPSON LABOR FORCE LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AMPSON LABOR FORCE LLC in 606 FLORIDA AVE NW, WASHINGTON, DC 20001 (NAICS 238160). OSHA activity number 346242738.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ampson Labor Force LLC — free Get an email when a new federal OSHA severe-injury report for Ampson Labor Force LLC is published. One employer, no account, unsubscribe in one click.
Site address
606 FLORIDA AVE NW
City
WASHINGTON
State
DC
ZIP
20001
Mailing
309 BURTMILLS AVE, SILVER SPRING, MD 20901
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 21, 2023
Abate by
Mar 29, 2023
Penalty
Initial $4,688 · Current $4,688
29 CFR  1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  a) On or about September 21, 2022; Roof area: Employees were conducting roof repair by applying sealant approximately 30-feet above the ground with no means of fall protection.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $4688

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 21, 2023
Abate by
Mar 29, 2023
Penalty
Initial $4,018 · Current $4,018
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) On or about September 21, 2022; Second Floor; Employees were using a Werner 6-foot A-frame stepladder to access the roof area in which the side rail was 4-feet below the landing.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $4018

1926.1053 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 21, 2023
Abate by
Mar 29, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(13): The top or top step of a stepladder was used as a step:  a) On or about September 21, 2022; Second Floor; Employees were using  the top step of the Werner 6-foot A-frame stepladder that was 4-feet below the landing to access the roof area.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.