Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUNERGY SOLAR LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SUNERGY SOLAR LLC in 850 BENT CREEK DRIVE, FORT PIERCE, FL 34947 (NAICS 238210). OSHA activity number 346243173.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sunergy Solar LLC — free Get an email when a new federal OSHA severe-injury report for Sunergy Solar LLC is published. One employer, no account, unsubscribe in one click.
Establishment
SUNERGY SOLAR LLC
Site address
850 BENT CREEK DRIVE
City
FORT PIERCE
State
FL
ZIP
34947
Mailing
7625 LITTLE ROAD SUITE 200A, NEW PORT RICHEY, FL 34654
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
5
Ownership type
A

7 citations on file for this inspection.

1903.19 C01

Other-than-serious 3 instances 3 exposed
Issued
Jul 26, 2023
Abate by
Aug 30, 2023
Penalty
Initial $501 · Current $501
29 CFR  1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  (a) On or about 07/11/2023, the employer failed to submit certification of corrective action for citation 1, item 1b issued on 03/22/2022, with an abatement due date of 04/10/2023.  (b) On or about 07/11/2023, the employer failed to submit certification of corrective action for citation 1, item 2b issued on 03/22/2022, with an abatement due date of 04/10/2023.  (c) On or about 07/11/2023, the employer failed to submit certification of corrective action for citation 1, item 3b issued on 03/22/2022, with an abatement due date of 04/10/2023.
Recent events (1)
  • — Z (O) $501

1926.501 B13

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 22, 2023
Penalty
Initial $3,572 · Current $3,572
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):  On or about September 23, 2022, on the south side roof of a residential structure located at 850 Bent Creek Drive in Fort Pierce, Florida, employees performing solar panel system installation work were exposed to a fall hazard of approximately 9 feet-8 inches while not being protected from falling to the lower level.
Recent events (1)
  • — Z (S) $3572

1926.503 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 22, 2023
Abate by
Apr 10, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  On or about September 23, 2022, on site of a residential structure located at 850 Bent Creek Drive in Fort Pierce, Florida, employees performing solar panel system installation work were exposed to a fall hazard from a roof prior to being provided with training for them to recognize and avoid the hazards associated with falling and the proper use of fall protection equipment.
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 22, 2023
Penalty
Initial $3,572 · Current $3,572
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  On or about September 23, 2022, at the north side roof edge of a residential structure located at 850 Bent Creek Drive in Fort Pierce, Florida, employees performing solar panel system installation work were exposed to a fall hazard of approximately 10 feet when utilizing a portable ladder that did not extend at least 3 feet above the upper landing surface.
Recent events (1)
  • — Z (S) $3572

1926.20 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 22, 2023
Abate by
Apr 10, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):  On or about September 23, 2022, on site of a residential structure located at 850 Bent Creek Drive in Fort Pierce, Florida, employees performing solar panel system installation work were exposed to fall hazards from a roof and a ladder prior to the employer performing an inspection of the site to ensure the employees were using the proper protection equipment and the equipment was being utilized correctly.
Recent events (1)
  • — Z (S) $0

1926.1053 B22

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 22, 2023
Penalty
Initial $3,572 · Current $3,572
29 CFR  1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause them to lose balance and fall:  On or about September 23, 2022, at the north side roof edge of a residential structure located at 850 Bent Creek Drive in Fort Pierce, Florida, an employee performing solar panel system installation work was exposed to a fall hazard of approximately 10 feet when utilizing a portable ladder while carrying a bucket filled with tools and materials that could potentially cause him to lose his balance and fall.
Recent events (1)
  • — Z (S) $3572

1926.1060 A

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 22, 2023
Abate by
Apr 10, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways:  On or about September 23, 2022, on site of a residential structure located at 850 Bent Creek Drive in Fort Pierce, Florida, employees performing solar panel system installation work were exposed to a fall hazard when utilizing a portable ladder to gain access to a roof prior to being provided with training for them to recognize and avoid the hazards associated with the use of  ladders.
Recent events (1)
  • — Z (S) $0

View Sunergy Solar LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346243173.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.