OSHA Inspection: BT SIEK COMPANY, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of BT SIEK COMPANY, INC. in 12350 INTERSTATE 45 N, WILLIS, TX 77378 (NAICS 238220). OSHA activity number 346243355.

Watch BT Siek Company, INC. — free Get an email when a new federal OSHA severe-injury report for BT Siek Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
12350 INTERSTATE 45 N
City
WILLIS
State
TX
ZIP
77378
Mailing
10704 NORTH FM 620, AUSTIN, TX 78726
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
13
Ownership type
A

3 citations on file for this inspection.

1926.350 A01

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $10151.00 · Current $0.00 Reduced
29 CFR  1926.350(a)(1): Valve protection caps shall be in place and secured.  On or about September 21, 2022 at the construction site, valve protection cap(s) were not in place and secured on a nitrogen compressed gas cylinder located on the eastside exterior of the employer's shipping container.
Recent events (2)
  • — I (S) $0
  • — Z (S) $10151

1926.350 A09

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.350(a)(9): Compressed gas cylinders shall be secured in an upright position at all times except, if necessary, for short periods of time while cylinders are actually being hoisted or carried.  On or about September 21, 2022 at the construction site, compressed gas cylinders located on the eastside exterior of the employer's shipping container were not secured in an upright position at all times.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.350 A10

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.350(a)(10):Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.  On or about September 21, 2022 at the construction site, oxygen cylinders in storage were stored immediately next to acetylene cylinders and diesel fuel cans.