SUPERIOR, WI —
OSHA Inspection: KENT PRECISION FOODS GROUP, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KENT PRECISION FOODS GROUP, INC. in 6120 TOWER AVE, SUPERIOR, WI 54880 (NAICS 311421). OSHA activity number 346250111.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KENT PRECISION FOODS GROUP, INC.
- Site address
- 6120 TOWER AVE
- City
- SUPERIOR
- State
- WI
- ZIP
- 54880
- Mailing
- 6120 TOWER AVE, SUPERIOR, WI 54880
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311421
- Employees
- 14
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.146 C02
- Issued
- Jan 13, 2023
- Abate by
- Feb 6, 2023
- Penalty
- Initial $8,718 · Current $6,103 Reduced
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: (a) Production and filling rooms; Danger signs or other equivalent means were not posted to notify employees of permit-required confined spaces including, but not limited to, a 500-gallon mixing tank and the cooling tunnel.
Recent events (2)
- — I (S) $6102.6
- — Z (S) $8718
1910.146 D
- Issued
- Jan 13, 2023
- Abate by
- Feb 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(d): Under the permit space program required by paragraph (c)(4) of this section the employer did not ensure that the requirements of (d)(1) through (d)(14) were met: (a) Production room; On or about August 1, 2022, entry was made into a 500-gallon batch mixing tank to inspect and service an internal spray ball mechanism. The employer's permit space program was not implemented with respect to this space prior to and during entry. (b) Lab area; On or about August 1, 2022, entry was made into a 650-gallon holding tank to inspect and service an internal spray ball mechanism. The employer's permit space program was not implemented with respect to this space prior to and during entry.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 G04
- Issued
- Jan 13, 2023
- Abate by
- Feb 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(g)(4): The employer did not certify that the training required by 29 CFR 1910.146(g)(1) through 29 CFR 1910.146(g)(3) had been accomplished: (a) Production room and lab area; On or about August 1, 2022, the employer did not certify that confined space training was accomplished prior to entry into permit spaces.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Jan 13, 2023
- Abate by
- Feb 6, 2023
- Penalty
- Initial $6,974 · Current $4,882 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Throughout the facility; The employer did not conduct periodic inspections of equipment-specific energy control procedures on at least an annual basis.
Recent events (2)
- — I (S) $4881.8
- — Z (S) $6974
1910.147 D03
- Issued
- Jan 13, 2023
- Abate by
- Feb 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Filling room; Employees perform lubricating, cleaning, set-up, and jam clearing tasks on the Federal Mfg. Co. model 2373GWSS2 bottle filler and capping machine without isolating the machine from energy source(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Jan 13, 2023
- Abate by
- Feb 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Filling room; Employees perform lubricating, cleaning, set-up and jam clearing tasks on the Federal Mfg. Co. model 2373GWSS2 bottle filler and capping machine without affixing lockout or tagout devices to the equipment's energy source(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A05
- Issued
- Jan 13, 2023
- Abate by
- Feb 6, 2023
- Penalty
- Initial $5,230 · Current $3,661 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: (a) On the wall between the filling and production rooms; Openings in the guarding of a Dayton brand model 144YU13, 24-inch exhaust fan, were approximately one-inch wide by two-inches long.
Recent events (2)
- — I (S) $3661
- — Z (S) $5230
More inspections at Kent Precision Foods Group, INC.
View Kent Precision Foods Group, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311421)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346250111.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.