Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KENT PRECISION FOODS GROUP, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KENT PRECISION FOODS GROUP, INC. in 6120 TOWER AVE, SUPERIOR, WI 54880 (NAICS 311421). OSHA activity number 346250111.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kent Precision Foods Group, INC. — free Get an email when a new federal OSHA severe-injury report for Kent Precision Foods Group, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6120 TOWER AVE
City
SUPERIOR
State
WI
ZIP
54880
Mailing
6120 TOWER AVE, SUPERIOR, WI 54880
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311421
Employees
14
Ownership type
A

7 citations on file for this inspection.

1910.146 C02

Serious Gravity 5 1 instance 14 exposed
Issued
Jan 13, 2023
Abate by
Feb 6, 2023
Penalty
Initial $8,718 · Current $6,103 Reduced
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces:  (a) Production and filling rooms; Danger signs or other equivalent means were not posted to notify employees of permit-required confined spaces including, but not limited to, a 500-gallon mixing tank and the cooling tunnel.
Recent events (2)
  • — I (S) $6102.6
  • — Z (S) $8718

1910.146 D

Serious Gravity 5 2 instances 2 exposed
Issued
Jan 13, 2023
Abate by
Feb 6, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.146(d): Under the permit space program required by paragraph (c)(4) of this section the employer did not ensure that the requirements of (d)(1) through (d)(14) were met:  (a) Production room; On or about August 1, 2022, entry was made into a 500-gallon batch mixing tank to inspect and service an internal spray ball mechanism.  The employer's permit space program was not implemented with respect to this space prior to and during entry.   (b) Lab area; On or about August 1, 2022, entry was made into a 650-gallon holding tank to inspect and service an internal spray ball mechanism.  The employer's permit space program was not implemented with respect to this space prior to and during entry.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 G04

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 13, 2023
Abate by
Feb 6, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.146(g)(4): The employer did not certify that the training required by 29 CFR 1910.146(g)(1) through 29 CFR 1910.146(g)(3) had been accomplished:  (a) Production room and lab area; On or about August 1, 2022, the employer did not certify that confined space training was accomplished prior to entry into permit spaces.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 13, 2023
Abate by
Feb 6, 2023
Penalty
Initial $6,974 · Current $4,882 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  (a) Throughout the facility; The employer did not conduct periodic inspections of equipment-specific energy control procedures on at least an annual basis.
Recent events (2)
  • — I (S) $4881.8
  • — Z (S) $6974

1910.147 D03

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 13, 2023
Abate by
Feb 6, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  (a) Filling room; Employees perform lubricating, cleaning, set-up, and jam clearing tasks on the Federal Mfg. Co. model 2373GWSS2 bottle filler and capping machine without isolating the machine from energy source(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 13, 2023
Abate by
Feb 6, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  (a) Filling room; Employees perform lubricating, cleaning, set-up and jam clearing tasks on the Federal Mfg. Co. model 2373GWSS2 bottle filler and capping machine without affixing lockout or tagout devices to the equipment's energy source(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A05

Serious Gravity 1 1 instance 8 exposed
Issued
Jan 13, 2023
Abate by
Feb 6, 2023
Penalty
Initial $5,230 · Current $3,661 Reduced
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:  (a)  On the wall between the filling and production rooms; Openings in the guarding of a Dayton brand model 144YU13, 24-inch exhaust fan, were approximately one-inch wide by two-inches long.
Recent events (2)
  • — I (S) $3661
  • — Z (S) $5230

View Kent Precision Foods Group, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346250111.