OSHA Inspection: ENERGY LIGHT, INC. DBA LIGHTMART.COM

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ENERGY LIGHT, INC. DBA LIGHTMART.COM in 1881 ROSE ROAD, LAKE ZURICH, IL 60047 (NAICS 335122). OSHA activity number 346256019.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Energy Light, INC. DBA Lightmart.Com — free Get an email when a new federal OSHA severe-injury report for Energy Light, INC. DBA Lightmart.Com is published. One employer, no account, unsubscribe in one click.
Site address
1881 ROSE ROAD
City
LAKE ZURICH
State
IL
ZIP
60047
Mailing
1881 ROSE ROAD, LAKE ZURICH, IL 60047
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335122
Employees
56
Ownership type
A

1 citation on file for this inspection.

1910.28 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 26, 2022
Abate by
Nov 15, 2022
Penalty
Initial $6,164 · Current $3,200 Reduced
29 CFR  1910.28(a)(1):1910.28(a)(1): The employer did not provide protection for each employee exposed to fall and falling object hazards. The employer did not ensure that all fall protection and falling object protection required by this section meet the criteria in � 1910.29, except that personal fall protection systems required by this section meet the criteria of � 1910.140.  a) Warehouse Area- On or about October 3, 2022, employees accessing racking, approximately 20 feet above the ground below, were not secured to a personal fall arrest systems or other means of fall protection, thereby exposing the employees to fall hazards.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $3200
  • — Z (S) $6164

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346256019.