Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CENVEO, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CENVEO, INC. in 14001 INWOOD ROAD, DALLAS, TX 75244 (NAICS 322230). OSHA activity number 346266315.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cenveo, INC. — free Get an email when a new federal OSHA severe-injury report for Cenveo, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
CENVEO, INC.
Site address
14001 INWOOD ROAD
City
DALLAS
State
TX
ZIP
75244
Mailing
14001 INWOOD ROAD, DALLAS, TX 75244
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
322230
Employees
214
Ownership type
A

5 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 10 1 instance 17 exposed
Issued
Feb 13, 2023
Abate by
Feb 24, 2023
Penalty
Initial $15,625 · Current $15,625
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  a)  This violation occurred on or about October 6, 2022 and at times prior thereto; when employees were operating the forklift without having formal instruction and practical training.
Recent events (2)
  • — C (S) $15625
  • — Z (S) $15625

1910.212 A01

Serious Gravity 10 3 instances 10 exposed
Issued
Feb 13, 2023
Abate by
Feb 24, 2023
Penalty
Initial $15,625 · Current $15,625
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  a) This violation occurred on or about October 6, 2022, and at times prior thereto; in production plant,  where employees were exposed to being caught-in or struck-by the unguarded pinch points created by rotating shafts:  a.  Envelope machine, FL Smithe, SW-5013, at the refeed/aligner section. b. Envelope machine, FL Smithe, SW-5021, at the Refeed/Aligner section. c. Envelope machine, FL Smithe, SW-5022, at the Refeed/Aligner section.
Recent events (2)
  • — C (S) $15625
  • — Z (S) $15625

1910.303 B02

Serious Gravity 5 3 instances 10 exposed
Issued
Feb 13, 2023
Abate by
Feb 24, 2023
Penalty
Initial $11,162 · Current $11,162
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  The employer did not ensure electrical equipment is used and installed in accordance with the listing or labeling instructions. This violation occurred on or about October 6, 2022, and at times prior thereto; in the production plant, envelope machines areas:  a) Power tap/power strip was being used to provide power to the light at envelope machine FL Smithe, SW-5013.  b) Power tap/power strip was being used to provide power to the light at envelope machine FL Smithe, SW-5021.  c) Power tap/power strip was being used to provide power to the light at envelope machine FL Smithe, SW-5022.
Recent events (2)
  • — C (S) $11162
  • — Z (S) $11162

1910.303 F02

Serious Gravity 5 3 instances 10 exposed
Issued
Feb 13, 2023
Abate by
Feb 24, 2023
Penalty
Initial $11,162 · Current $11,162
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  a) This violation occurred on or about October 6, 2022, and at times prior thereto; In production plant, where circuit breaker panels were not marked to indicate the purpose of individual breakers.  a.  Panel A, in folding area. b.  Panel 277B, in folding area. c.  Panel 277-3, in shipping area (upstairs).
Recent events (2)
  • — C (S) $11162
  • — Z (S) $11162

1910.303 G01

Serious Gravity 5 1 instance 8 exposed
Issued
Feb 13, 2023
Abate by
Feb 24, 2023
Penalty
Initial $11,162 · Current $11,162
29 CFR  1910.303(g)(1):  Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.   a) On or about October 6, 2022, and at times prior thereto; In shipping department, electrical disconnect and transformer were blocked by large commercial printer, boxes and materials.