Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RIO GRANDE ENVIRONMENTAL

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of RIO GRANDE ENVIRONMENTAL in 3320 S RICHFIELD WAY, AURORA, CO 80013 (NAICS 562910). OSHA activity number 346270051.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RIO Grande Environmental — free Get an email when a new federal OSHA severe-injury report for RIO Grande Environmental is published. One employer, no account, unsubscribe in one click.
Site address
3320 S RICHFIELD WAY
City
AURORA
State
CO
ZIP
80013
Mailing
8430 HOPE CT., DENVER, CO 80229
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562910
Employees
12
Ownership type
A

2 citations on file for this inspection.

1926.1101 G03 III

Other-than-serious Gravity 1 2 instances 3 exposed
Issued
Feb 3, 2023
Penalty
Initial $2,678 · Current $2,678

Hazardous substances 9020

29 CFR  1926.1101(g)(3)(iii):Dust and debris containing asbestos containing material and presumed asbestos containing material were dry swept, shoveled or removed by other dry clean-up methods:  a)3320 S Richfield Street Aurora, CO 80013: On or about October 7, 2022, employees were exposed to unnecessary and additional airborne asbestos fibers while in an asbestos containment. Friable asbestos was being removed (e.g. drywall texture). The employer failed to ensure brooms were not utilized in containment to prevent dry sweeping. The area where the broom was located was not wet.
Recent events (2)
  • — I (O) $2678
  • — Z (S) $2678

1926.1101 G05 I B 2

Other-than-serious Gravity 1 1 instance 2 exposed
Issued
Feb 3, 2023
Penalty
Initial $2,678 · Current $2,678
29 CFR  1926.1101(g)(5)(i)(B)(2):Electrical circuits in the enclosure were not deactivated or equipped with ground-fault circuit interrupters:  a) 3320 S Richfield Way Aurora, CO 80013: On or about October 6, 2022, employees were exposed to electrical hazards. The employer did not ensure all the circuits within the negative pressure enclosure were either deactivated or equipped with a ground fault circuit interrupter.
Recent events (2)
  • — I (O) $2678
  • — Z (S) $2678

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346270051.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.