WASHINGTON, DC —
OSHA Inspection: SAMUEL BANKS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SAMUEL BANKS in 4717 DIX STREET NE, WASHINGTON, DC 20019 (NAICS 236118). OSHA activity number 346271810.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAMUEL BANKS
- Site address
- 4717 DIX STREET NE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20019
- Mailing
- 4409 LANCEFIELD LANE, BOWIE, MD 20720
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Mar 31, 2023
- Abate by
- Apr 10, 2023
- Penalty
- Initial $2,277 · Current $1,366 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a) On or about October 4, 2022; Second Floor /deck; Employees performing framing work were operating pneumatic equipment including, but not limited to, nail guns without the use of eye protection. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1366
- — Z (S) $2277
1926.404 B01 II
- Issued
- Mar 31, 2023
- Abate by
- Apr 10, 2023
- Penalty
- Initial $4,688 · Current $2,813 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20-ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection. On or about October 4, 2022; Basement Area; throughout the site; Employees worked in a wet environment operating double-insulated electrical equipment including, but not limited to, portable circular saws and air compressors powered by temporary wiring without ground-fault circuit interrupters in place to protect from electrical shock. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2813
- — Z (S) $4688
1926.405 B01
- Issued
- Mar 31, 2023
- Abate by
- Apr 10, 2023
- Penalty
- Initial $4,688 · Current $2,813 Reduced
General-duty citation text
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed: On or about October 4, 2022; Basement Area; Employees were exposed to an approximate 1-inch knockout opening that was not covered, in a wet environment, on a panel box supplying 120-volts of electrical power to equipment and tools. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2813
- — Z (S) $4688
1926.405 E01
- Issued
- Mar 31, 2023
- Abate by
- Apr 10, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed so as to prevent moisture or water from entering and accumulating within the enclosures: a) On or about October 4, 2022; Basement Area; Employees were exposed to an electrical panel box and one 120-volt four-outlet receptacle that was subject to rain and water drainage as a result of the basement area not being finished. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Mar 31, 2023
- Abate by
- Apr 10, 2023
- Penalty
- Initial $4,688 · Current $2,813 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): On or about October 4, 2022; Second Floor/Residential Home; Employees worked in a wet environment conducting framing , such as installing decking, approximately 20 feet above the ground level without any means of fall protection. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2813
- — Z (S) $4688
More inspections in this industry (NAICS 236118)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346271810.