OSHA Inspection: SAMUEL BANKS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SAMUEL BANKS in 4717 DIX STREET NE, WASHINGTON, DC 20019 (NAICS 236118). OSHA activity number 346271810.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Samuel Banks — free Get an email when a new federal OSHA severe-injury report for Samuel Banks is published. One employer, no account, unsubscribe in one click.
Establishment
SAMUEL BANKS
Site address
4717 DIX STREET NE
City
WASHINGTON
State
DC
ZIP
20019
Mailing
4409 LANCEFIELD LANE, BOWIE, MD 20720
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
8
Ownership type
A

5 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 31, 2023
Abate by
Apr 10, 2023
Penalty
Initial $2,277 · Current $1,366 Reduced
29 CFR  1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.   a) On or about October 4, 2022; Second Floor /deck; Employees performing framing work were operating pneumatic equipment including, but not limited to, nail guns without the use of eye protection.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1366
  • — Z (S) $2277

1926.404 B01 II

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 31, 2023
Abate by
Apr 10, 2023
Penalty
Initial $4,688 · Current $2,813 Reduced
29 CFR  1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20-ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection.  On or about October 4, 2022; Basement Area;  throughout the site; Employees worked in a wet environment operating double-insulated electrical equipment including, but not limited to, portable circular saws and air compressors powered by temporary wiring without ground-fault circuit interrupters in place to protect from electrical shock.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2813
  • — Z (S) $4688

1926.405 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 31, 2023
Abate by
Apr 10, 2023
Penalty
Initial $4,688 · Current $2,813 Reduced
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed:  On or about October 4, 2022; Basement Area;  Employees were exposed to an approximate 1-inch knockout opening that was not covered, in a wet environment, on a panel box supplying 120-volts of electrical power to equipment and tools.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2813
  • — Z (S) $4688

1926.405 E01

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 31, 2023
Abate by
Apr 10, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.405(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed so as to prevent moisture or water from entering and accumulating within the enclosures:  a) On or about October 4, 2022; Basement Area; Employees were exposed to an electrical panel box and one 120-volt four-outlet receptacle that was subject to rain and water drainage as a result of the basement area not being finished.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 31, 2023
Abate by
Apr 10, 2023
Penalty
Initial $4,688 · Current $2,813 Reduced
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):   On or about October 4, 2022; Second Floor/Residential Home; Employees worked in a wet environment conducting framing , such as installing decking, approximately 20 feet above the ground level without any means of fall protection.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2813
  • — Z (S) $4688