PHOENIX, AZ —
OSHA Inspection: AZ ARMY NATIONAL GUARD-USPFO
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of AZ ARMY NATIONAL GUARD-USPFO in 5555 E. MCDOWELL ROAD BLDG 5820, PHOENIX, AZ 85008 (NAICS 493110). OSHA activity number 346278807.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AZ ARMY NATIONAL GUARD-USPFO
- Site address
- 5555 E. MCDOWELL ROAD BLDG 5820
- City
- PHOENIX
- State
- AZ
- ZIP
- 85008
- Mailing
- 5645 E. MCDOWELL ROAD, PHOENIX, AZ 85008
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 27
- Ownership type
- D
Citations
9 citations on file for this inspection.
1910.132 D01
- Issued
- Nov 29, 2022
- Abate by
- Dec 6, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(1):The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): a) BATTERY CHARGING STATION: Employees recharging the Doosan forklift battery were exposed to with battery acid and an assessment had not been conducted to determine the hazards present and necessary PPE, exposing employees to chemical burns from accidental contact.
Recent events (1)
- — Z (S) $0
1910.132 D01 I
- Issued
- Nov 29, 2022
- Abate by
- Dec 6, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(1)(i):The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: a) BATTERY CHARGING STATION: Employees refilled the Doosan forklift battery and were not provided with proper PPE, exposing them to injury from accidental contact with battery acid.
Recent events (1)
- — Z (S) $0
1910.303 B02
- Issued
- Nov 29, 2022
- Abate by
- Dec 6, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) SHIPPING AREA: A two-gang metal outlet box used to provide power to the palletizer was installed so that it hung from a flexible cord, exposing employees to electrocution hazards.
Recent events (1)
- — Z (S) $0
1910.305 G01 III
- Issued
- Nov 29, 2022
- Abate by
- Dec 6, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iii):Flexible cords used as permitted in paragraphs (g)(1)(ii)(C), (g)(1)(ii)(G), or (g)(1)(ii)(I) of 29 CFR 1910.305 were not energized from an approved receptacle outlet: a)BREAKROOM: A relocatable power tap was used to provide power to the drinking fountain, exposing employees to fire and electrical hazards.
Recent events (1)
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Nov 29, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) AREA D: Employees were exposed to fire and electrical hazards where a triple tap extension cord was used to power two Helmer upright refrigerators.
Recent events (1)
- — Z (S) $0
1910.305 G02 III
- Issued
- Nov 29, 2022
- Abate by
- Dec 6, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii):Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) BREAKROOM: A drinking fountain power cord was connected to a relocatable power tap, with the power cord supporting the weight of the relocatable power tap exposing employees to electrocution hazards.
Recent events (1)
- — Z (S) $0
1910.305 J02 IV
- Issued
- Nov 29, 2022
- Abate by
- Dec 6, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location: a) BREAKROOM: A two receptacle outlet located under the drinking fountain was not protected by a GFCI, exposing employees to fire and electrocution hazards.
Recent events (1)
- — Z (S) $0
1910.1200 E01
- Issued
- Nov 29, 2022
- Abate by
- Dec 6, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer had not developed or implemented a written hazard communication program that included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): a) USPFO: Employees worked with chemicals such as bleach, battery acid, and paint, and there was no hazard communication program in place, exposing employees to health hazards.
Recent events (1)
- — Z (S) $0
1910.1200 F06 I
- Issued
- Nov 29, 2022
- Abate by
- Dec 6, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v) a) SHIPPING AREA: A spray bottle containing clear liquid was not labeled to identify its contents, exposing employees to hazards from improper use. b) WASTE STORAGE AREA: A 55-gallon barrel of contaminated fuel was not appropriately labeled to warn employees of the hazardous nature of the contents.
Recent events (1)
- — Z (S) $0
More inspections at AZ Army National Guard-Uspfo
View AZ Army National Guard-Uspfo's full OSHA safety record →
More inspections in this industry (NAICS 493110)
More inspections in AZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346278807.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.