OSHA Inspection: PREMIER HOTELS & RESORTS GUAM, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PREMIER HOTELS & RESORTS GUAM, INC. in 470 FARENHOLT AVE, TAMUNING, GU 96913 (NAICS 721110). OSHA activity number 346279722.

Watch Premier Hotels & Resorts Guam, INC. — free Get an email when a new federal OSHA severe-injury report for Premier Hotels & Resorts Guam, INC. is published. One employer, no account, unsubscribe in one click.
Site address
470 FARENHOLT AVE
City
TAMUNING
State
GU
ZIP
96913
Mailing
470 FARENHOLT AVE, TAMUNING, GU 96913
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721110
Employees
193
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $5594.00 · Current $3916.00 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  A) In Guest Room 806: There was no established lockout tagout program to instruct on how to replace the blower of an air conditioning unit.  Employees were exposed to laceration and electrical hazards.  B) Guest Room: There was was no established lockout tagout program to instruct on how to perform replacement of a fan coil unit to perform maintenance of an air conditioning unit. Employees were exposed to laceration and electrical hazards.
Recent events (2)
  • — I (S) $3915.8
  • — Z (S) $5594

1910.213 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $7925.00 · Current $5548.00 Reduced
29 CFR  1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  Plant Room: The blade above the table portion of a  homemade table saw used to cut wood was not guarded.  Employees were exposed to laceration and amputation hazards.
Recent events (2)
  • — I (S) $5547.5
  • — Z (S) $7925

1910.37 A04

Other-than-serious 1 instance 23 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:  Service Elevator Lobby: The emergency light did not work when tested.  Employees were exposed to fire and evacuation hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B02

Other-than-serious 1 instance 23 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Maintenance Area Office, under the bulletin board: A relocatable power tap secured to the wall with screws, was used to provide power to two Ridgid battery chargers. Employees were exposed to fire and electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 3 instances 23 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  A) Maintenance Area Office, next to Siemens Exhaust Fan shut-off and Right-To-Know Station: Access to three electrical panels was blocked by storage.  Employees were exposed to electrical hazards.  B) Plant Room, Maintenance Work Area, by chop saw: Access to electrical panel was blocked by storage.  Employees were exposed to electrical hazards.  C) Plant Room, Back, switches CHWP-1 and CHWP-4: Access to emergency shut-offs was blocked by storage.  Employees were exposed to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View PREMIER HOTELS & RESORTS GUAM, INC.'s full OSHA safety record →