AUBURN, NY —
OSHA Inspection: CORROSION CONTROL, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CORROSION CONTROL, INC. in 10 QUARRY ROAD, AUBURN, NY 13021 (NAICS 325998). OSHA activity number 346286784.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CORROSION CONTROL, INC.
- Site address
- 10 QUARRY ROAD
- City
- AUBURN
- State
- NY
- ZIP
- 13021
- Mailing
- 10 QUARRY ROAD, AUBURN, NY 13021
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- Employees
- 11
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 27, 2023
- Abate by
- Jun 9, 2023
- Penalty
- Initial $6,250 · Current $4,688 Reduced
E101
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire, explosion, and deflagration hazards: (a) 10 Quarry Road, Auburn NY, 13021, on or about October 18, 2022, equipment such as, but not limited to, the powder coating operation and dust collection system were being utilized to apply and move 720A009 Greenbar, which is a combustible dust. The equipment contained explosive atmospheres during normal operation. The employer did not ensure that the equipment and areas were equipped and maintained with means of protection to prevent explosions, fires, and deflagrations.
Recent events (2)
- — I (S) $4687.5
- — Z (S) $6250
1910.176 C
- Issued
- Jan 27, 2023
- Abate by
- Mar 3, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.176(c): Housekeeping. Storage areas were not kept free from accumulation of materials that constitute hazards from fire or explosion. (a) Dust Collector Room, 10 Quarry Road, Auburn NY, 13021, on or about October 18, 2022, the employer did not ensure the workplace was free from the accumulation of combustible dusts, including but not limited to 720A009 Greenbar.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.307 C
- Issued
- Jan 27, 2023
- Abate by
- May 2, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.307(c): Electrical equipment in a hazardous (classified) location was not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: (a) Power Supply at Powder Coat Booth, 10 Quarry Road, Auburn NY, 13021, on or about October 18, 2022, the employer did not ensure that electrical installations including, but not limited to, outlet receptacles used for plugging in equipment at the powder coating booth, were intrinsically safe, explosion proof, approved for Class II, Division 2 locations. Dusts present in the area were classified as Class II with explosion severity of 1.25 Newton and Kst values of 29.51 bar*meters per second exposing employees to explosion and fire hazards at the powder coating booth and in the dust collector room. (b) Outlet behind ITW Gema Dust Collector, 10 Quarry Road, Auburn NY, 13021, on or about October 18, 2022, the employer did not ensure that electrical installations including, but not limited to, outlet receptacles used for plugging in equipment behind the dust collector, were intrinsically safe, explosion proof, approved for Class II, Division 2 locations. Dusts present in the area were classified as Class II with explosion severity of 1.25 Newton and Kst values of 29.51 bar*meters per second exposing employees to explosion and fire hazards at the powder coating booth and in the dust collector room. Abatement certification is required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Corrosion Control, INC.
View Corrosion Control, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325998)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346286784.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.