Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GENERAL ALUM NEW ENGLAND CORP.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GENERAL ALUM NEW ENGLAND CORP. in 34 KIDDER POINT ROAD, SEARSPORT, ME 04974 (NAICS 325180). OSHA activity number 346288657.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch General Alum NEW England Corp. — free Get an email when a new federal OSHA severe-injury report for General Alum NEW England Corp. is published. One employer, no account, unsubscribe in one click.
Site address
34 KIDDER POINT ROAD
City
SEARSPORT
State
ME
ZIP
04974
Mailing
34 KIDDER POINT ROAD, SEARSPORT, ME 04974
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325180
Employees
30
Ownership type
A

5 citations on file for this inspection.

1910.23 B10

Serious Gravity 1 1 instance 15 exposed
Issued
Jan 9, 2023
Penalty
Initial $3,698 · Current $2,589 Reduced
29 CFR 1910.23(b)(10): The employer did not ensure that any ladder with structural or other defects as immediately tagged "Dangerous: Do Not Use" or with similar language in accordance with � 1910.145 and removed from service until repaired in accordance with � 1910.22(d), or replaced:  South Storage Bay Entrance for Sulfate Product - The employer did not ensure that the fixed ladder with a dented frame was immediately tagged "Dangerous: Do Not Use" or with similar language and removed from service until repaired or replaced.
Recent events (2)
  • — I (S) $2588.6
  • — Z (S) $3698

1910.28 B03 I

Serious Gravity 5 1 instance 15 exposed
Issued
Jan 9, 2023
Penalty
Initial $6,164 · Current $4,315 Reduced
29 CFR 1910.28(b)(3)(i): The employer did not ensure that each employee is protected from falling through any hole (including skylights) that is 4 feet (1.2 m) or more above a lower level by one or more of the following methods listed in 29 CFR 1910.28(b)(3)(i)(A)-(D):  Shaker Room in the Sulfate Building - The employer did not ensure that each employee was protected from falling through the hole in the second floor shaker room that is 4 feet (1.2 m) or more above a lower level by one or more of the following methods listed in 29 CFR 1910.28(b)(3)(i)(A)-(D).
Recent events (2)
  • — I (S) $4314.8
  • — Z (S) $6164

1910.36 G02

Serious Gravity 1 1 instance 15 exposed
Issued
Jan 9, 2023
Penalty
Initial $3,698 · Current $2,589 Reduced
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points:  Sulfate Building, Beside the Bagging Area  - The scale created an exit access that was not at least 28 inches (71.1 cm) wide at all points.
Recent events (2)
  • — I (S) $2588.6
  • — Z (S) $3698

1910.147 C04 II B

Serious Gravity 5 1 instance 15 exposed
Issued
Jan 9, 2023
Abate by
Apr 10, 2023
Penalty
Initial $6,164 · Current $4,315 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:  Sulfate Building - The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing the bagging machine.
Recent events (2)
  • — I (S) $4314.8
  • — Z (S) $6164

1910.303 G01

Other-than-serious 1 instance 15 exposed
Issued
Jan 9, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  Sulfate Building, Beside Bagging and Scale Area - The 120 volt electrical panel was blocked.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View General Alum NEW England Corp.'s full OSHA safety record →