OSHA Inspection: MULTI-WING AMERICA, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MULTI-WING AMERICA, INC. in 15030 BERKSHIRE INDUSTRIAL PARK, MIDDLEFIELD, OH 44062 (NAICS 423830). OSHA activity number 346294713.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Multi-Wing America, INC. — free Get an email when a new federal OSHA severe-injury report for Multi-Wing America, INC. is published. One employer, no account, unsubscribe in one click.
Site address
15030 BERKSHIRE INDUSTRIAL PARK
City
MIDDLEFIELD
State
OH
ZIP
44062
Mailing
15030 BERKSHIRE INDUSTRIAL PARK, MIDDLEFIELD, OH 44062
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423830
Employees
65
Ownership type
A

1 citation on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 13, 2022
Abate by
Feb 1, 2023
Penalty
Initial $7,252 · Current $7,252
29 CFR  1910.147(c)(1):Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.  On or about October 14, 2022, the employer did not establish an energy control program consisting of energy control procedures, employee training, and periodic inspections.  Employees were not protected from the unexpected energization, startup, or release of stored energy while performing servicing and maintenance activities, such as, unjamming and repairing a loading dock leveler.  Energy sources included, but not limited to, electrical and pneumatic energy and gravity.
Recent events (1)
  • — Z (S) $7252