MIDDLEFIELD, OH —
OSHA Inspection: MULTI-WING AMERICA, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MULTI-WING AMERICA, INC. in 15030 BERKSHIRE INDUSTRIAL PARK, MIDDLEFIELD, OH 44062 (NAICS 423830). OSHA activity number 346294713.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MULTI-WING AMERICA, INC.
- Site address
- 15030 BERKSHIRE INDUSTRIAL PARK
- City
- MIDDLEFIELD
- State
- OH
- ZIP
- 44062
- Mailing
- 15030 BERKSHIRE INDUSTRIAL PARK, MIDDLEFIELD, OH 44062
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423830
- Employees
- 65
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 C01
- Issued
- Dec 13, 2022
- Abate by
- Feb 1, 2023
- Penalty
- Initial $7,252 · Current $7,252
General-duty citation text
29 CFR 1910.147(c)(1):Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. On or about October 14, 2022, the employer did not establish an energy control program consisting of energy control procedures, employee training, and periodic inspections. Employees were not protected from the unexpected energization, startup, or release of stored energy while performing servicing and maintenance activities, such as, unjamming and repairing a loading dock leveler. Energy sources included, but not limited to, electrical and pneumatic energy and gravity.
Recent events (1)
- — Z (S) $7252
More inspections in this industry (NAICS 423830)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346294713.