TOTOWA, NJ —
OSHA Inspection: STANPAC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of STANPAC in 10 WEST END RD, TOTOWA, NJ 07512 (NAICS 322219). OSHA activity number 346302730.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STANPAC
- Site address
- 10 WEST END RD
- City
- TOTOWA
- State
- NJ
- ZIP
- 07512
- Mailing
- 10 WEST END ROAD, TOTOWA, NJ 07512
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322219
- Employees
- 63
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.37 B04
- Issued
- Mar 23, 2023
- Penalty
- Initial $8,929 · Current $6,250 Reduced
General-duty citation text
29 CFR 1910.37(b)(4):Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: a) At or near 10 West End Rd., Totowa NJ: employees were exposed to smoke inhalation while working inside a facility where the direction of travel to the Exits was not immediately apparent, on or about 10/27/22
Recent events (2)
- — I (S) $6250.3
- — Z (S) $8929
1910.147 C04 II
- Issued
- Mar 23, 2023
- Penalty
- Initial $8,929 · Current $6,250 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a) At or near 10 West End Rd, Totowa NJ - Thermals: The employer did not have specific procedural steps for controlling hazardous energy while performing servicing and maintenance activities on Thermals, on or about 10/25/22.
Recent events (2)
- — I (S) $6250.3
- — Z (S) $8929
1910.147 C06 I
- Issued
- Mar 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a)At or near 10 West End Rd, Totowa NJ - Thermal: The employer did not perform periodic inspections of the company energy control procedures. This condition was observed, on or about 10/25/22.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Mar 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a) At or near 10 West End Rd, Totowa NJ - Cup Forming # 8: The employer did not provide training for Thermal crew who was required to work on equipment, on or about 10/25/22
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 M05 I
- Issued
- Mar 23, 2023
- Penalty
- Initial $11,162 · Current $7,813 Reduced
General-duty citation text
29 CFR 1910.178(m)(5)(i): When a powered industrial truck is left unattended, load engaging means were not fully lowered, controls were not netralized, power was not shut off, and brakes set. a) At or near 10 West End Rd, Totowa NJ: employees were exposed to struck by hazards while working around an unatended forklift with its load engaging means elevated approximately 8 feet , on or about 10/27/22
Recent events (2)
- — I (S) $7813.4
- — Z (S) $11162
1910.212 A01
- Issued
- Mar 23, 2023
- Penalty
- Initial $15,625 · Current $10,938 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) At or near 10 West End Rd, Totowa NJ - Cup Forming # 8: An employee was exposed to an amputation/laceration hazard from an inefective guarded equipment. On 10/25/22 an employee sustained an injury left hand while removing piece of paper from machine in operation.
Recent events (2)
- — I (S) $10937.5
- — Z (S) $15625
1910.242 B
- Issued
- Mar 23, 2023
- Penalty
- Initial $8,929 · Current $6,250 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) At or near 10 West End Rd, Totowa NJ: Employees were exposed to struck by hazards while cleaning with compressed air nozzles that were putting out pressure of approximately 97.9 p.s.i., on or about 10/27/22. b) At or near 10 West End Rd., Totowa NJ - Entrance of Production Area: An employee was cleaning himself with an air hose, on or about 10/25/22.
Recent events (2)
- — I (S) $6250.3
- — Z (S) $8929
More inspections at Stanpac
View Stanpac's full OSHA safety record →
More inspections in this industry (NAICS 322219)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346302730.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.