Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HANSA CONSULT OF NORTH AMERICA, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of HANSA CONSULT OF NORTH AMERICA, LLC in 5409 AIRPORT SERVICE ROAD, TAMPA, FL 33607 (NAICS 237120). OSHA activity number 346308315.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hansa Consult of North America, LLC — free Get an email when a new federal OSHA severe-injury report for Hansa Consult of North America, LLC is published. One employer, no account, unsubscribe in one click.
Site address
5409 AIRPORT SERVICE ROAD
City
TAMPA
State
FL
ZIP
33607
Mailing
200 INTERNATIONAL DRIVE, PORTSMOUTH, NH 03801
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237120
Employees
1
Ownership type
A

4 citations on file for this inspection.

1910.146 D03 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Dec 15, 2022
Abate by
Jan 12, 2023
Penalty
Initial $4,144 · Current $0 Reduced
29 CFR  1910.146(d)(3)(i):Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices necessary for safe permit space entry operations, including specifying acceptable entry conditions  a) At a sump located at 5409 Airport Service Road, Tampa, FL: On or about 10/27/2022, the employer exposed employees to electrocution and explosion hazards, in that, the employer directed employees to conduct work in confined spaces without ensuring the atmosphere of the space was tested before entry.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4144

1910.146 D04 I

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Dec 15, 2022
Abate by
Jan 12, 2023
Penalty
Initial $0 · Current $2,486
29 CFR  1910.146(d)(4)(i):Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not ensure that employees used the testing and monitoring equipment properly  a) At a sump located at 5409 Airport Service Road, Tampa, FL: On or about 10/27/2022, the employer exposed employees to electrocution and explosion hazards, in that, employees were conducting work in confined spaces without using testing and monitoring equipment.
Recent events (2)
  • — I (O) $2486.4
  • — Z (S) $0

1910.146 D04 II

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Dec 15, 2022
Abate by
Jan 12, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.146(d)(4)(ii):Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not provide, at no cost to the employees, ventilating equipment needed to obtain acceptable entry conditions  a) At a sump located at 5409 Airport Service Road, Tampa, FL: On or about 10/27/2022, the employer exposed employees to electrocution and explosion hazards, in that, employees were conducting work in confined spaces without using fans to provide proper ventilation.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.147 A03 I

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Dec 15, 2022
Abate by
Jan 12, 2023
Penalty
Initial $4,144 · Current $2,486 Reduced
29 CFR  1910.147(a)(3)(i):The employer did not utilize procedures for affixing appropriate lockout devices or tagout devices to energy isolating devices, and to otherwise disable machines or equipment to prevent unexpected energization, start up or release of stored energy in order to prevent injury to employees.  a) At a sump located at 5409 Airport Service Road, Tampa, FL: On or about 10/27/2022 and at times prior, the employer exposed employees to electrocution and explosion hazards, in that, the employer directed employees to conduct work in areas that require lockout/tagout procedures without ensuring those procedures were being followed.
Recent events (2)
  • — I (O) $2486.4
  • — Z (S) $4144

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346308315.