OSHA Inspection: URNEX BRANDS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of URNEX BRANDS, INC. in 700 EXECUTIVE BOULEVARD, ELMSFORD, NY 10523 (NAICS 325611). OSHA activity number 346315310.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Urnex Brands, INC. — free Get an email when a new federal OSHA severe-injury report for Urnex Brands, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
URNEX BRANDS, INC.
Site address
700 EXECUTIVE BOULEVARD
City
ELMSFORD
State
NY
ZIP
10523
Mailing
700 EXECUTIVE BOULEVARD, ELMSFORD, NY 10523
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325611
Employees
95
Ownership type
A

1 citation on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 20, 2023
Abate by
Feb 23, 2023
Penalty
Initial $10,046 · Current $10,046
29 CFR  1910.147(c)(1):Energy control program. The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:   location: production floor on or about: 10/17/22  a) The employer did not have an adequate energy control program, including specific energy control procedures and employee training on isolating machines or equipment from energy sources.  Employees maintain and service equipment including but not limited to the OMAG C3 vertical form/fill/seal machine.  NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.