OSHA Inspection: ILLINOIS PIPING CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ILLINOIS PIPING CORPORATION in 7000 S ADAMS STREET ROD MILL, PEORIA, IL 61641 (NAICS 332996). OSHA activity number 346315807.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Illinois Piping Corporation — free Get an email when a new federal OSHA severe-injury report for Illinois Piping Corporation is published. One employer, no account, unsubscribe in one click.
Site address
7000 S ADAMS STREET ROD MILL
City
PEORIA
State
IL
ZIP
61641
Mailing
2323 SOUTHWEST WASHINGTON STREET, PEORIA, IL 61602
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332996
Employees
55
Ownership type
A

5 citations on file for this inspection.

1926.501 B04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 20, 2023
Abate by
Apr 18, 2023
Penalty
Initial $10,938 · Current $9,750 Reduced
29 CFR  1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes:   On or about October 25, 2022, an employee working in the reheat furnace was exposed to floor holes approximately 13 feet deep and the employer failed to ensure each hole was covered.
Recent events (2)
  • — I (S) $9750
  • — Z (S) $10938

1926.503 A02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 20, 2023
Abate by
Apr 18, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.503(a)(2)(i): Employees were not trained, as necessary, by a competent person qualified to recognize the nature of fall hazards in the work area:   On or about October 25, 2022, an employee working in the reheat furnace was exposed to fall hazards of approximately 13 feet from open floor holes and the employer failed to train each employee on the fall hazards in the reheat furnace and the methods to be used to control or eliminate the hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 I03

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 20, 2023
Abate by
Apr 18, 2023
Penalty
Initial $10,938 · Current $0 Reduced
29 CFR  1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees:  On or about October 17, 2022, employees working in the reheat furnace were exposed to approximately 13 foot fall hazards from open floor holes and the employer failed to ensure the plywood used to cover the holes were secured to prevent displacement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $10938

1926.502 I04

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 20, 2023
Abate by
Apr 18, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard:  On or about October 17, 2022, employees working in the reheat furnace were exposed to approximately 13 foot fall hazards from open floor holes and the employer failed to ensure the plywood used to cover the holes was marked to indicate the holes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1203 A

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 20, 2023
Abate by
Apr 18, 2023
Penalty
Initial $10,938 · Current $9,750 Reduced
29 CFR  1926.1203(a): Before work began at the worksite, the employer did not ensure that a competent person identified all confined spaces in which one or more of the employees it directed may have worked, and/or did not identify each space that was a permit space, through consideration and evaluation of the elements of that space, including testing as necessary:  On or about October 17, 2022, employees working in the reheat furnace were exposed to approximately 13 foot fall hazards from open floor holes and the employer failed to evaluate and identify the furnace as a confined space and if the space was permit-required.
Recent events (2)
  • — I (S) $9750
  • — Z (S) $10938