OSHA Inspection: SCHINDLER ELEVATOR CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SCHINDLER ELEVATOR CORPORATION in 11013 AIRPORT HWY, SWANTON, OH 43558 (NAICS 333921). OSHA activity number 346315849.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Schindler Elevator Corporation — free Get an email when a new federal OSHA severe-injury report for Schindler Elevator Corporation is published. One employer, no account, unsubscribe in one click.
Site address
11013 AIRPORT HWY
City
SWANTON
State
OH
ZIP
43558
Mailing
1530 TIMBERWOLF DRIVE, HOLLAND, OH 43528
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333921
Employees
40
Ownership type
A

2 citations on file for this inspection.

1910.147 D

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Dec 29, 2022
Penalty
Initial $8,287 · Current $0 Reduced
29 CFR  1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):   a. Schindler Elevator Corporation, at a worksite located at 11013 Airport Hwy, Swanton, Ohio 43558: On or about October 31, 2022, the employer did not ensure energy control applications steps to control the electrical and mechanical energy sources on a Montgomery Escalator were implemented prior to an employee performing step removal activities. Employees performing these work task in an energized condition were exposed to caught in hazards while removing step bolts and removal of steps.
Recent events (3)
  • — F (S) $0
  • — C (S) $8287
  • — Z (S) $8287

1910.147 F01 II

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Dec 29, 2022
Abate by
Jan 25, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(1)(ii): Employees were not removed from the machine or equipment area in accordance with paragraph (e)(2) of this section during testing or positioning of machines, equipment or components thereof:  a. Schindler Elevator Corporation, at a worksite located at 11013 Airport Hwy, Swanton, Ohio 43558: On or about October 31, 2022, the employer did not ensure that all employees were safely positioned or removed from the pit area on the downside of a Montgomery Escalator, when the escalator was energized/jogged in order to re-position escalator steps for removal. Employees performing this activitiy in this condition were exposed to caught in hazards between the step and deck plate.