JOINT BASE LEWIS MCCHORD, WA —
OSHA Inspection: ARMY & AIR FORCE EXCHANGE SERVICE-PENDLETON EXPRESS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ARMY & AIR FORCE EXCHANGE SERVICE-PENDLETON EXPRESS in 3145 PENDLETON AVE, JOINT BASE LEWIS MCCHORD, WA 98433 (NAICS 447110). OSHA activity number 346318256.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARMY & AIR FORCE EXCHANGE SERVICE-PENDLETON EXPRESS
- Site address
- 3145 PENDLETON AVE
- City
- JOINT BASE LEWIS MCCHORD
- State
- WA
- ZIP
- 98433
- Mailing
- 9503 RAINIER DRIVE MS 46, JOINT BASE LEWIS MCCHORD, WA 98433
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 447110
- Employees
- 14
- Ownership type
- D
Citations
3 citations on file for this inspection.
1910.22 A01
- Issued
- Dec 2, 2022
- Abate by
- Jan 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 910.22(a)(1): 29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition: a) Storage Room, where the placement of items including signs, display cases, display racks, and bags of ice melt created tripping hazards and impeded ingress and egress to the storage room.
Recent events (1)
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Dec 2, 2022
- Abate by
- Jan 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure: a) Office, where a yellow extension cord was used to supply power to the electronic equipment located in the Network Switch Modem.
Recent events (1)
- — Z (O) $0
1910.1200 G08
- Issued
- Dec 2, 2022
- Abate by
- Jan 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical: a) Facility, where safety data sheets were not maintained for compressed gases including propane and carbon dioxide.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 447110)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346318256.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.