Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. DEPT. OF INTERIOR, NATIONAL PARK SERVICE, LASSEN VOLCANIC NATIONAL PARK, HEADQUARTERS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. DEPT. OF INTERIOR, NATIONAL PARK SERVICE, LASSEN VOLCANIC NATIONAL PARK, HEADQUARTERS in 38050 HIGHWAY 36 EAST P.O. BOX 100, MINERAL, CA 96063 (NAICS 712190). OSHA activity number 346321854.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Dept. of Interior, National Park Service, Lassen Volcanic National Park, Headquarters — free Get an email when a new federal OSHA severe-injury report for U.S. Dept. of Interior, National Park Service, Lassen Volcanic National Park, Headquarters is published. One employer, no account, unsubscribe in one click.
Site address
38050 HIGHWAY 36 EAST P.O. BOX 100
City
MINERAL
State
CA
ZIP
96063
Mailing
38050 HIGHWAY 36 EAST P.O. BOX 100, MINERAL, CA 96063
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
30
Ownership type
D

8 citations on file for this inspection.

1910.28 B02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 24, 2023
Abate by
May 18, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.28(b)(2)(i): Employee(s) in a hoist area were not protected from falling 4 feet (1.2 m) or more to a lower level by a guardrail system, a personal fall arrest system, or a travel restraint system:  Lassen Volcanic National Park, North District Maintenance Facility: The mezzanine hoisting area was not provided with any type of fall protection. Employees who access the area were exposed to an 8 foot fall.
Recent events (1)
  • — Z (S) $0

1910.37 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 24, 2023
Abate by
May 18, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(1): Exit routes were not kept free of explosive or highly flammable furnishings or other decorations.  Lassen Volcanic National Park, Headquarters, Building 22: Two propane cylinders were left near the exit to the building. Employees were exposed to fire hazards
Recent events (1)
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 24, 2023
Abate by
May 18, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch:  Lassen Volcanic National Park, Headquarters, Building 23, Auto shop: The Wissota 6 inch bench grinder (Model E33M) left tongue guard was not adjusted to 1/4 of an inch. The tongue guard opening measured 1 1/4 of an inch. Employees were exposed to face, body and mid-section injuries.
Recent events (1)
  • — Z (S) $0

1910.157 E03

Repeat Gravity 1 5 instances 5 exposed
Issued
Apr 24, 2023
Abate by
May 18, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:    Lassen Volcanic National Park: In the following buildings, the fire extinguishers had not received annual maintenance check since April, 2021.  1- Headquarters, Building # 22 2- Headquarters, Building #23 Auto Shop 3- Headquarters, Building # 27 Sign Shop 4-North District Maintenance Facility 5-North District Fee office.   The U.S. Dept. of Interior, National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.157(e)(3), which was contained in OSHA inspection number 1515054, citation number 02, item number 001 and was affirmed as a final order on 05/27/2021, with respect to a workplace located at Sequoia & Kings Canyon, Red Fir Facility, 64600 Generals Highway, Three Rivers, CA 93271.  The U.S. Dept. of Interior, National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.157(e)(3), which was contained in OSHA inspection number 1515048, citation number 02, item number 001 and was affirmed as a final order on 05/07/2021, with respect to a workplace located at Sequoia & Kings Canyon, Grant Grove Facility, 83715 Park Road, King Canyon, CA 93633.  The U.S. Dept. of Interior, National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.157(e)(3), which was contained in OSHA inspection number 1515061, citation number 02, item number 001 and was affirmed as a final order on 05/27/2021, with respect to a workplace located at Sequoia & Kings Canyon, Clover Creek Wastewater Plant, 64100 Generals Highway, Three Rivers, CA 93271.
Recent events (1)
  • — Z (R) $0

1910.212 A01

Repeat Gravity 5 2 instances 2 exposed
Issued
Apr 24, 2023
Abate by
May 18, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Lassen Volcanic National Park, Headquarters: In the following locations equipment was not provided with chuck guards. Employees were exposed to point of operation and flying debris hazards.   Building 23, Auto shop: 1- The South Bend G-26T lathe (Government # NP8000080203) was missing the chuck guard.                                                  2- The 20 inch Jet drill press (Serial # 19045927) was not provided with a chuck guard.  Building 27, Sign shop: The Powermatic drill press (Serial # 22038062) was not provided with a chuck guard.   The U.S. Dept. of Interior, National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 1487343, citation number 01, item number 02 and was affirmed as a final order on 10/20/2020, with respect to a workplace located at 5083 Foresta Road, P.O. Box 700W, El Portal, CA 95318  The U.S. Dept. of Interior, National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 1515056, citation number 01, item number 03 and was affirmed as a final order on 05/27/2021, with respect to a workplace located at Ash Mountain Maintenance Facility, 47050 Generals Highway, Three Rivers, CA 93271  The U.S. Dept. of Interior, National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 1515061, citation number 02, item number 02 and was affirmed as a final order on 05/27/2021, with respect to a workplace located at Clover Creek Wastewater Plant, 64100 Generals Highway, Three Rivers, CA 93271
Recent events (1)
  • — Z (R) $0

1910.213 C01

Repeat Gravity 5 1 instance 2 exposed
Issued
Apr 24, 2023
Abate by
May 18, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  North District Maintenance Facility, Building 544: The 10 inch CRAFTSMAN Professional table saw (Model No. 351226940) used for ripping purposes, was not provided with a blade guard that adjusts to the thickness of the materials being cut and remains in contact with it. Employees were exposed to severe laceration and or amputation related injuries.  The U.S. Dept. of Interior, National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard29 CFR 1910.213(c)(1), which was contained in OSHA inspection number 1430593, citation number 02, item number 04 and was affirmed as a final order on 10/25/2019, with respect to a workplace located at Pinnacles National Park East, 5000 Highway 146, Paicines, CA 95043.
Recent events (1)
  • — Z (R) $0

1910.242 B

Repeat Gravity 1 2 instances 2 exposed
Issued
Apr 24, 2023
Abate by
May 18, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i:  Lassen Volcanic National Park: In the following locations, the compressed air used for cleaning measured over 100 psi.  1- Headquarters, Building 23, Auto shop. 2- North District Maintenance Facility   The U.S. Dept. of Interior, National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.242(b), which was contained in OSHA inspection number 1515048, citation number 02, item number 04 and was affirmed as a final order on 05/07/2021, with respect to a workplace located at Sequoia & Kings The U.S. Dept. of Interior, National Park Service was previously cited for a violation of this Canyon, Grant Grove, 83715 Park Road, Kings Canyon, CA 93633
Recent events (1)
  • — Z (R) $0

1910.303 G01

Repeat Gravity 1 1 instance 3 exposed
Issued
Apr 24, 2023
Abate by
May 18, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:   North District Fee Office Storage area / Garage: The Electrical Panel was blocked by storage and equipment. Employees were unable to access the electrical equipment immediately in case of an emergency.  The U.S. Dept. of Interior, National Park Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.303(g)(1), which was contained in OSHA inspection number 1430593, citation number 01, item number 002 and was affirmed as a final order on 10/25/2019, with respect to a workplace located at Pinnacles National Park East, 5000 Highway 146, Paicines, CA 95043.
Recent events (1)
  • — Z (R) $0

View U.S. Dept. of Interior, National Park Service, Lassen Volcanic National Park, Headquarters's full OSHA safety record →