Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EGINITY, INC.

Monitoring inspection · Safety discipline

On , OSHA opened a monitoring safety inspection of EGINITY, INC. in 624 DOUGLAS AVE SUITE 1412, ALTAMONTE SPRINGS, FL 32714 (NAICS 493110). OSHA activity number 346322365.

Watch Eginity, INC. — free Get an email when a new federal OSHA severe-injury report for Eginity, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
EGINITY, INC.
Site address
624 DOUGLAS AVE SUITE 1412
City
ALTAMONTE SPRINGS
State
FL
ZIP
32714
Mailing
624 DOUGLAS AVE SUITE 1412, ALTAMONTE SPRINGS, FL 32714
Inspection type
Monitoring (D)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
20
Ownership type
A

2 citations on file for this inspection.

1910.37 A03

Serious Gravity 5 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $4144.00 · Current $2486.00 Reduced
29 CFR  1910.37(a)(3):Exit route(s) were not kept free and unobstructed:   a). On or about November 3, 2002, at the warehouse located at 624 Douglas Ave suite 1412 Altamonte Springs, FL 32714, employees were exposed to fire and smoke inhalation hazards, in that the emergency exit doors were obstructed by pallets and an inoperable forklift.
Recent events (2)
  • — I (S) $2486.4
  • — Z (S) $4144

1910.303 G01 VI B

Other-than-serious 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $465.00 · Current $279.00 Reduced
29 CFR  1910.303(g)(1)(vi)(B): A three foot minimum clearance was not maintained for headroom of working spaces about service equipment, switchboards, panel boards, or motor control centers.  a). On or about 11/03/2022, at the warehouse located at 624 Douglas Ave suite 1412 Altamonte Springs, FL 32714, employees were exposed to electric shock hazards in that the minimum clearance was not maintained around the electrical panels. The electrical panel boxes were obstructed with cardboard and other materials stacked in front of them.
Recent events (2)
  • — I (O) $279
  • — Z (O) $465

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346322365.