MANSFIELD, TX —
OSHA Inspection: ALFONSO LAZO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALFONSO LAZO in 506 ANTLER DR., MANSFIELD, TX 76063 (NAICS 238350). OSHA activity number 346324619.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALFONSO LAZO
- Site address
- 506 ANTLER DR.
- City
- MANSFIELD
- State
- TX
- ZIP
- 76063
- Mailing
- 710 WESTMOUNT AVE., DALLAS, TX 75211
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B02
- Issued
- Nov 7, 2022
- Abate by
- Dec 7, 2022
- Penalty
- Initial $2,486 · Current $2,486
General-duty citation text
29 CFR 1926.451(b)(2):Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and/or walkway was not at least 18 inches (46 cm) wide: On or about November 3, 2022, and times prior thereto, employees engaged in cornice work on a residential home from single pole scaffold, work from a platform not 18 inches wide. The employees were exposed to potential fall hazard of approximately 12 feet to the ground below.
Recent events (1)
- — Z (S) $2486
1926.451 G01 VII
- Issued
- Nov 7, 2022
- Abate by
- Dec 7, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. On or about November 3, 2022, and times prior thereto, employees work from a pole scaffold without fall protection systems while installing cornice material on the exterior of a residential home. The employee was exposed to fall hazards of approximately 12 feet to the ground below.
Recent events (1)
- — Z (S) $0
1926.452 A04
- Issued
- Nov 7, 2022
- Abate by
- Dec 7, 2022
- Penalty
- Initial $1,865 · Current $1,865
General-duty citation text
29 CFR 1926.452(a)(4): Diagonal bracing in both directions were not installed across the entire outside face of all double- and single-pole scaffolds. On or about November 3, 2022, and times prior thereto, working from a pole scaffold without cross bracing installed were exposed to a collapse and falling approximately 12 feet to the ground below.
Recent events (1)
- — Z (S) $1865