HUDSON, WI —
OSHA Inspection: TECHO EXTERIORS AND RESTORATION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TECHO EXTERIORS AND RESTORATION LLC in 1800 LILLIAN DR, HUDSON, WI 54016 (NAICS 238160). OSHA activity number 346325483.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TECHO EXTERIORS AND RESTORATION LLC
- Site address
- 1800 LILLIAN DR
- City
- HUDSON
- State
- WI
- ZIP
- 54016
- Mailing
- 14750 W BURNSVILLE PKWY LOT 108, BURNSVILLE, MN 55306
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1903.19 C01
- Issued
- Apr 12, 2023
- Abate by
- May 19, 2023
- Penalty
- Initial $376 · Current $376
General-duty citation text
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: (a) Citation 1, Item 1a; a serious violation of 29 CFR 1926.501(b)(13) with an abatement date of March 17, 2023. (b) Citation 1, Item 1b; a serious violation of 29 CFR 1926.503(a)(1) with an abatement date of March 17, 2023.
Recent events (1)
- — Z (O) $376
1903.19 D01
- Issued
- Apr 12, 2023
- Abate by
- May 19, 2023
- Penalty
- Initial $376 · Current $376
General-duty citation text
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required: (a) Citation 1, Item 1a; a serious violation of 29 CFR 1926.501(b)(13) with an abatement date of March 17, 2023. (b) Citation 1, Item 1b; a serious violation of 29 CFR 1926.503(a)(1) with an abatement date of March 17, 2023.
Recent events (1)
- — Z (O) $376
1926.501 B13
- Issued
- Mar 3, 2023
- Abate by
- Mar 17, 2023
- Penalty
- Initial $4,688 · Current $4,688
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Residential roof, various locations; One or more methods of fall protection was not in place while employees performed work from a 6-8:12 pitch roof at heights ranging between approximately 13 feet, 6 inches to 21 feet, 10 inches above ground level.
Recent events (1)
- — Z (S) $4688
1926.503 A01
- Issued
- Mar 3, 2023
- Abate by
- Mar 17, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) Residential roof, various locations; Employee(s) exposed to fall hazards were not adequately trained to recognize fall hazards and/or the procedures to be followed to minimize fall hazards.
Recent events (1)
- — Z (S) $0
1926.1053 B01
- Issued
- Mar 3, 2023
- Penalty
- Initial $3,349 · Current $3,349
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder: (a) In front of garage; A 28-foot Werner Model D1328-2 aluminum extension ladder placed at ground level and leaned against the peak to access the roof, was not of sufficient height to allow for the side rails to extend at least 3 feet above the landing surface, was not equipped with a grasping device(s) and was not effectively secured to prevent displacement.
Recent events (1)
- — Z (S) $3349
More inspections at Techo Exteriors and Restoration LLC