Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JRT ELECTRIC LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JRT ELECTRIC LLC in ALTAY DR AND AMUR DR, BILLINGS, MT 59106 (NAICS 238210). OSHA activity number 346327158.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JRT Electric LLC — free Get an email when a new federal OSHA severe-injury report for JRT Electric LLC is published. One employer, no account, unsubscribe in one click.
Establishment
JRT ELECTRIC LLC
Site address
ALTAY DR AND AMUR DR
City
BILLINGS
State
MT
ZIP
59106
Mailing
1310 SOUTH EAST 46TH ST, AMARILLO, TX 79118
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
11
Ownership type
A

1 citation on file for this inspection.

1926.453 B02 V

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 2, 2023
Abate by
Mar 1, 2023
Penalty
Initial $3,572 · Current $3,572
29 CFR  1926.453(b)(2)(v):A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: Note:  As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system.  The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated.  a) Intersection of Altay Drive and Amur Drive, Billings, MT:  On or about November 6, 2022, and at times prior, employees were exposed to catapult and subsequent fall hazards of approximately 35 feet to the ground below while operating an Genie S-65 Aerial Lift at a commercial apartment building.
Recent events (1)
  • — Z (S) $3572

View JRT Electric LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346327158.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.