Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARMY & AIR FORCE EXCHANGE SERVICE- LEWIS NORTH EXPRESS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ARMY & AIR FORCE EXCHANGE SERVICE- LEWIS NORTH EXPRESS in 11566 41ST DIVISION DR, JOINT BASE LEWIS MCCHORD, WA 98433 (NAICS 447110). OSHA activity number 346328909.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Army & AIR Force Exchange Service- Lewis North Express — free Get an email when a new federal OSHA severe-injury report for Army & AIR Force Exchange Service- Lewis North Express is published. One employer, no account, unsubscribe in one click.
Site address
11566 41ST DIVISION DR
City
JOINT BASE LEWIS MCCHORD
State
WA
ZIP
98433
Mailing
9503 RAINIER DRIVE MS 46, JOINT BASE LEWIS MCCHORD, WA 98433
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
447110
Employees
28
Ownership type
D

7 citations on file for this inspection.

1910.132 D01

Serious Gravity 1 1 instance 28 exposed
Issued
Dec 2, 2022
Abate by
Jan 23, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):  a) Facility, where employees were required to change-out the propane cylinders on the forklifts, hand protection such as, insulated gloves suitable for low temperatures were not provided.
Recent events (1)
  • — Z (S) $0

1910.132 F01 II

Serious Gravity 1 1 instance 28 exposed
Issued
Dec 2, 2022
Abate by
Jan 23, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.132(f)(1)(ii): The employer did not provide training to each employee who is required by this section to use PPE on knowing what PPE is necessary:  a) Facility, where the employer did not provide training that addressed the need for hand protection such as, insulated gloves suitable for low temperatures, during the change-out of propane cylinders on the forklifts.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 2 instances 28 exposed
Issued
Dec 2, 2022
Abate by
Jan 23, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a)  Cashier Station 3, where flexible cords used as substitute for fixed wiring included:  1. An orange extension cord was used to supply power to the Coke cooler.  2. An orange extension cord was used to supply power to the Super Coffee cooler.
Recent events (1)
  • — Z (S) $0

1910.36 G02

Other-than-serious 1 instance 28 exposed
Issued
Dec 2, 2022
Abate by
Jan 23, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points:  a) Stock Room, where the placement of boxes and pallets adjacent to the back wall reduced the aisle way width to 25 inches.
Recent events (1)
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 28 exposed
Issued
Dec 2, 2022
Abate by
Jan 23, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a) Stock Room, where boxes of merchandise and pallets were stored in front of circuit panel labeled FC1.
Recent events (1)
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 1 instance 28 exposed
Issued
Dec 2, 2022
Abate by
Jan 23, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  a) Stock Room, where the outlet located adjacent to circuit panel FC1 was equipped with a damaged face plate.
Recent events (1)
  • — Z (O) $0

1910.1200 G08

Other-than-serious 1 instance 28 exposed
Issued
Dec 2, 2022
Abate by
Jan 23, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):  The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical:  a) Facility, where safety data sheets were not maintained for compressed gases including propane and carbon dioxide.