Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BIND-RITE SERVICES INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BIND-RITE SERVICES INC in 16 HORIZON BLVD, SOUTH HACKENSACK, NJ 07606 (NAICS 323113). OSHA activity number 346329287.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bind-Rite Services INC — free Get an email when a new federal OSHA severe-injury report for Bind-Rite Services INC is published. One employer, no account, unsubscribe in one click.
Site address
16 HORIZON BLVD
City
SOUTH HACKENSACK
State
NJ
ZIP
07606
Mailing
16 HORIZON BLVD, SOUTH HACKENSACK, NJ 07606
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323113
Employees
245
Ownership type
A

7 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 2 instances 245 exposed
Issued
May 1, 2023
Abate by
Jun 16, 2023
Penalty
Initial $8,036 · Current $4,425 Reduced
29 CFR  1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  a) Bin-Rite Services Inc, Binders, Stiches and Wire O machines: The employer did not establish an energy control program consisting of procedures or employee training  and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative , on or about 11/7/22   b) Bin-Rite Services Inc, Binders, Stitches and Wire O machines: The employer did not establish an energy control program consisting of procedures or employee training  and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative , on or about 4/26/23.
Recent events (2)
  • — I (S) $4425
  • — Z (S) $8036

1910.147 C04 I

Serious Gravity 5 2 instances 245 exposed
Issued
May 1, 2023
Abate by
Jun 16, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:(a)(LOCATION)(IDENTIFY SPECIFIC OPERATIONS AND/OR CONDITIONS)(IDENTIFY MACHINERY OR EQUIPMENT)(THIS INCLUDES ENFORCEMENT OF PROCEDURES)  a) Bin-Rite Services Inc: The employer did not develop detailed site specific procedural steps for shutting down the Trimmers, Binders, Stitches and wire O Machinery prior to maintenance/servicing, to prevent unexpected release of stored energy, thus exposing employees to an accident, on or about 11/7/22.   b)  Bin-Rite Services Inc: The employer did not develop detailed site specific procedural steps for shutting down the Trimmers, Binders, stitches and wire O Machinery prior to maintenance/servicing, to prevent unexpected release of stored energy, thus exposing employees to an accident, on or about 4/26/23.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C05 I

Serious Gravity 5 2 instances 245 exposed
Issued
May 1, 2023
Abate by
Jun 16, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:  a) Warehouse : The employer did not provide locks, tags, wedges, key blocks, adapter pins, self locking fasteners or other hardware for isolating, securing or blocking Trimmers, Binders and wire O  Machines from energy  sources, on or about 11/7/22.    b) Warehouse : The employer did not provide locks, tags, wedges, key blocks, adapter pins, self locking fasteners or other hardware for isolating, securing or blocking Trimmers, Binders and wire O  Machines from energy  sources, on or about 4/26/23.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 2 instances 245 exposed
Issued
May 1, 2023
Abate by
Jun 16, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees  a) Warehouse : The employer did not provide training to ensure that employees have the knowledge and understanding of the use of a lock out tag out program and the dangers of the energy of the machines, on or about 11/7/22.  b) Warehouse : The employer did not provide training to ensure that employees have the knowledge and understanding of the use of a lock out tag out program and the dangers of the energy of the machines, on or about 4/26/23.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L04 III

Serious Gravity 1 2 instances 2 exposed
Issued
May 1, 2023
Penalty
Initial $6,026 · Current $3,325 Reduced
29 CFR  1910.178(l)(4)(iii):An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  a) Warehouse: Employees were allowed to operate powered industrial truck without being evaluated t least once every three years, on or about 11/7/22
Recent events (2)
  • — I (S) $3325
  • — Z (S) $6026

1910.212 A03 II

Serious Gravity 5 3 instances 245 exposed
Issued
May 1, 2023
Penalty
Initial $8,036 · Current $4,425 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a) Warehouse: Stitcher # 4 did not have the point of operation guarded to prevent employee exposure to an amputation hazard from the unguarded ram nip points, on or about 11/7/22.  b) Warehouse: Stitcher # 4 did not have the point of operation guarded to prevent employee exposure to an amputation hazard from the unguarded ram nip points, on or about 4/26/23.  c) Warehouse Stitcher # 3  did not have the point of operation guarded to prevent employee exposure to an amputation hazard from the unguarded ram nip points, on or about 4/26/23.  d) Warehouse Binder #1 did not have the point of operation guarded to prevent employee exposure to an amputation hazard from the unguarded ram nip points, on or about 4/26/23.
Recent events (2)
  • — I (S) $4425
  • — Z (S) $8036

1910.305 G01 IV

Serious Gravity 1 2 instances 245 exposed
Issued
May 1, 2023
Penalty
Initial $6,026 · Current $3,325 Reduced
29 CFR  1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv)   a) Building Interior: Employees were using relocatable power taps and flexible cords as a substitute for the fixed wiring of a structure to power the machinery and equipment, on or about 11/7/23.
Recent events (2)
  • — I (S) $3325
  • — Z (S) $6026

View Bind-Rite Services INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346329287.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.