OSHA Inspection: SYMRISE

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of SYMRISE in 209 SCM RD., BRUNSWICK, GA 31523 (NAICS 325998). OSHA activity number 346329758.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Symrise — free Get an email when a new federal OSHA severe-injury report for Symrise is published. One employer, no account, unsubscribe in one click.
Establishment
SYMRISE
Site address
209 SCM RD.
City
BRUNSWICK
State
GA
ZIP
31523
Mailing
209 SCM RD., BRUNSWICK, GA 31523
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325998
Employees
39
Ownership type
A

1 citation on file for this inspection.

1910.119 J02

Serious Gravity 5 1 instance 39 exposed
Issued
May 4, 2023
Abate by
Jun 30, 2023
Penalty
Initial $12,278 · Current $7,367 Reduced
29 CFR 1910.119(j)(2): The employer failed to develop and/or implement mechanical integrity inspection and test procedures.    (a) The employer failed to develop an effective written mechanical integrity (MI) procedure for pressurized piping inspections when pressurized piping was inspected using procedures that did not establish a set of specific actions and strategies detailing the scope, extent, methods and timing of specific inspection activities in order to determine the condition of pressurized piping based on defined/expected damage. Actions and strategies that were not addressed in the inadequate procedure include but are not limited to the following:     1) define the type(s) of inspection needed, (e.g. internal, external, on-stream, nonintrusive);  2) identify the next inspection date for each inspection type;  3) describe the inspection methods and NDE techniques;  4) describe the extent and locations of inspection and NDE at CMLs;  5) describe the surface cleaning requirements needed for inspection and examinations for each type of inspection;  6) describe the requirements of any needed pressure test (e.g. type of test, test pressure, test temperature, and duration);  7) describe any required repairs if known or previously planned before the upcoming inspection.  8) describe the types of damage anticipated or experienced in the piping systems;  9) define the location of the expected damage;  10) define any special access and preparation needed.    Pressurized piping inspected using inadequate written procedures include at least the alpha-pinene, hydrogen, nitrogen, and cis-pinene piping associated with R-501. This condition exposed employees to the hazard of explosion/fire. This violation was observed at Symrise Inc. on or about February 28, 2023, located at 209 SCM Road, Brunswick, Georgia.
Recent events (2)
  • — I (S) $7366.8
  • — Z (S) $12278

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346329758.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.