Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INLINER SOLUTIONS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of INLINER SOLUTIONS, LLC in 137 NORTH ELLIOTT AVE BEHIND HOMEOWNER HOUSE, SANFORD, FL 32771 (NAICS 562998). OSHA activity number 346329907.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Inliner Solutions, LLC — free Get an email when a new federal OSHA severe-injury report for Inliner Solutions, LLC is published. One employer, no account, unsubscribe in one click.
Site address
137 NORTH ELLIOTT AVE BEHIND HOMEOWNER HOUSE
City
SANFORD
State
FL
ZIP
32771
Mailing
2601 STOUT HERITAGE PKWY. SUITE 100, PLAINFIELD, IN 46168
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562998
Employees
61
Ownership type
A

2 citations on file for this inspection.

1910.333 C03

Deleted Serious Gravity 10 1 instance 6 exposed
Issued
Mar 10, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR  1910.333(c)(3): When work was to be performed near overhead lines, the lines were not deenergized and grounded, nor were other protective measures provided before work was started.  a) Jobsite: City Alleyway, Sanford Florida 32771: On or about November 3, 2022, overhead powerlines were not deenergized or grounded while installing liners to the drainpipes, exposing employees to 7,620 Volts electrical shock and burn hazards, on or about November 3, 2022.
Recent events (3)
  • — F (S) $0
  • — C (S) $15625
  • — Z (S) $15625

1910.333 C03 III A

Serious Gravity 10 1 instance 6 exposed
Issued
Mar 10, 2023
Penalty
Initial $15,625 · Current $15,625
29 CFR  1910.333(c)(3)(iii)(A):Vehicles or mechanical equipment capable of having parts of their structures elevated near energized overhead lines were not operated so that a clearance of 10 feet (305 cm) plus 4 inches (10 cm) for every 10 kV over 50 kV.   a) Jobsite: City Alleyway, Sanford Florida 32771: elevated work platform was located within eighteen (18) inches from an energized 7,620 Volts powerline, while employees were installing a drain pipe liner, exposing employees to electrical shock and burn hazards, on or about November 3, 2022.
Recent events (3)
  • — F (S) $15625
  • — C (S) $15625
  • — Z (S) $15625

View Inliner Solutions, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346329907.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.