Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FLX LINE-X

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FLX LINE-X in 875 STATE RTE 5 AND 20, GENEVA, NY 14456 (NAICS 441310). OSHA activity number 346329931.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch FLX Line-X — free Get an email when a new federal OSHA severe-injury report for FLX Line-X is published. One employer, no account, unsubscribe in one click.
Establishment
FLX LINE-X
Site address
875 STATE RTE 5 AND 20
City
GENEVA
State
NY
ZIP
14456
Mailing
875 STATE RTE 5 AND 20, GENEVA, NY 14456
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441310
Employees
9
Ownership type
A

6 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 17, 2023
Abate by
Apr 21, 2023
Penalty
Initial $1,707 · Current $1,707
29 CFR  1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use.   a. FLX LINE-X, 875 State Route 5 And 20, Geneva, NY 14456.  On or about November 3, 2022, the employer did not develop and implement a written respiratory protection program when requiring employees to wear a 3M 7503 half-face air purifying respirator.  b. FLX LINE-X, 875 State Route 5 And 20, Geneva, NY 14456.  On or about November 3, 2022, the employer did not develop and implement a written respiratory protection program when requiring employees to wear an Allegro 9901 full-face supplied air respirator connected to an Allegro 9815-EF breathing air blower.   Abatement certification must be submitted for this item.
Recent events (1)
  • — Z (S) $1707

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 17, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before employees were fit tested or required to use the respirator in the workplace:   a. FLX LINE-X, 875 State Route 5 And 20, Geneva, NY 14456.  On or about November 3, 2022, the employer did not provide a medical evaluation to determine employee's ability to use a respirator, before the employee was fit tested or required to use a 3M 7503 half-face air purifying respirator.  b. FLX LINE-X, 875 State Route 5 And 20, Geneva, NY 14456.  On or about November 3, 2022, the employer did not provide a medical evaluation to determine employee's ability to use a respirator, before the employee was fit tested or required to use an Allegro 9901 full-face supplied air respirator connected to an Allegro 9815-EF breathing air blower.
Recent events (1)
  • — Z (S) $0

1910.134 F01

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 17, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.134(f)(1): The employer did not ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test or quantitative fit test:   a. FLX LINE-X, 875 State Route 5 And 20, Geneva, NY 14456.  On or about November 3, 2022, the employer did not ensure that an employee using a tight-fitting facepiece respirator, a 3M 7503 half-face air purifying respirator,  pass an appropriate qualitative fit test or quantitative fit test.  b. FLX LINE-X, 875 State Route 5 And 20, Geneva, NY 14456.  On or about November 3, 2022, the employer did not ensure that an employee using a tight-fitting facepiece respirator, an Allegro 9901 full-face supplied air respirator, pass an appropriate qualitative fit test or quantitative fit test.
Recent events (1)
  • — Z (S) $0

1910.134 H01

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 17, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.134(h)(1): The employer did not ensure respirators were cleaned and disinfected using the procedures in Appendix B-2 of 29 CFR 1910.134 or equivalent procedures recommended by the respirator manufacturer:  a. FLX LINE-X, 875 State Route 5 And 20, Geneva, NY 14456.  On or about November 3, 2022, the employer did not ensure the 3M 7503 half-face air purifying respirator was cleaned and disinfected using the procedures in Appendix B-2 of 29 CFR 1910.134 or equivalent procedures recommended by the respirator manufacturer.  b. FLX LINE-X, 875 State Route 5 And 20, Geneva, NY 14456.  On or about November 3, 2022, the employer did not ensure the Allegro 9901 full-face supplied air respirator was cleaned and disinfected using the procedures in Appendix B-2 of 29 CFR 1910.134 or equivalent procedures recommended by the respirator manufacturer.
Recent events (1)
  • — Z (S) $0

1910.134 H02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 17, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.134(h)(2)(i): The employer did not ensure respirators were stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:   a. FLX LINE-X, 875 State Route 5 And 20, Geneva, NY 14456.  On or about November 3, 2022, the employer did not ensure the 3M 7503 half-face air purifying respirator was stored to protect it from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  was not packed or stored to prevent deformation of the facepiece and exhalation valve.  b. FLX LINE-X, 875 State Route 5 And 20, Geneva, NY 14456.  On or about November 3, 2022, the employer did not ensure the Allegro 9901 full-face supplied air respirator was stored to protect it from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  was not packed or stored to prevent deformation of the facepiece and exhalation valve.
Recent events (1)
  • — Z (S) $0

1910.134 K

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 17, 2023
Abate by
May 3, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.134(k): The employer did not provide effective respirator training to employees that was comprehensive, understandable and recur annually to employees required to use respiratory protection:   a. FLX LINE-X, 875 State Route 5 And 20, Geneva, NY 14456.  On or about November 3, 2022, the employer did not provide respirator training to employees required to use a 3M 7503 half-face air purifying respirator.   b. FLX LINE-X, 875 State Route 5 And 20, Geneva, NY 14456.  On or about November 3, 2022, the employer did not provide respirator training to employees required to use an Allegro 9901 full-face supplied air respirator connected to an Allegro 9815-EF breathing air blower.   Abatement certification must be submitted for this item.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346329931.