Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CLARK DIETRICH BUILDING SYSTEMS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CLARK DIETRICH BUILDING SYSTEMS in 1455 RIDGE ROAD, VIENNA, OH 44473 (NAICS 332322). OSHA activity number 346330145.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Clark Dietrich Building Systems — free Get an email when a new federal OSHA severe-injury report for Clark Dietrich Building Systems is published. One employer, no account, unsubscribe in one click.
Site address
1455 RIDGE ROAD
City
VIENNA
State
OH
ZIP
44473
Mailing
1455 RIDGE ROAD, VIENNA, OH 44473
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
160
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 10, 2023
Abate by
Mar 2, 2023
Penalty
Initial $11,162 · Current $7,813 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:   On or about October 18, 2022, the employer did not ensure energy control procedures were utilized when an employee performed service and maintenance activities when performing a die test on Line 79 cutoff shear.
Recent events (2)
  • — I (S) $7813.4
  • — Z (S) $11162

1910.147 D

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Feb 10, 2023
Abate by
Mar 2, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):(a)   On or about October 18, 2022 the employer failed to ensure that the energy isolating devices of Line 79 cutoff shear were located and operated to isolate the energy sources. An employee reached into the gear driven trolley system and entered the hazardous area of the equipment while it was in operation during service and maintenance activities when performing a die test on Line 79 cutoff shear. Employees were exposed to amputation hazard associated with the accidental release of energy during the servicing of the Line 79 cutoff shear. The employer failed to implement energy control application steps as the engine cylinders were not closed or covered to perform the servicing work [per the 1910.147(d)(2) requirement]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3), LOTO device application [(d)(4), dissipation of residual energy [(d)(5)(I)], and verification of isolation [(d)(6), were not implemented to protect employees from machine servicing hazards.  Prepare for shutdown [(d)(1)] - ensure authorized employee has knowledge of the type, magnitude, the hazards, and the method or means to control the energy;  Shutdown the machine or equipment [(d)(2)];  Machine isolation [(d)(3)] - Physically locate and operate all energy isolation devices that are needed to control the energy to the machine or equipment in such a manner as to isolate the machine or equipment from the energy source(s);  LOTO device application [(d)(4)] - Affix a lockout or tagout device to each energy isolating device;  Dissipation of residual energy [(d)(5)(i)] - relieve, disconnect, restrain, and otherwise render safe all potentially hazardous stored or residual energy;  Verification of isolation [(d)(6)] - Verify that isolation and deenergization of the machine or equipment has been accomplished.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Clark Dietrich Building Systems's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346330145.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.