ELMHURST, IL —
OSHA Inspection: SEMBLEX CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SEMBLEX CORPORATION in 900 N. CHURCH ROAD, ELMHURST, IL 60126 (NAICS 336390). OSHA activity number 346337934.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SEMBLEX CORPORATION
- Site address
- 900 N. CHURCH ROAD
- City
- ELMHURST
- State
- IL
- ZIP
- 60126
- Mailing
- 900 CHURCH ROAD, ELMHURST, IL 60126
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336390
- Employees
- 304
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C07 I A
- Issued
- Mar 17, 2023
- Abate by
- Apr 29, 2024
- Penalty
- Initial $15,625 · Current $9,375 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. On or about November 3, 2022, set up employee(s) did not receive training in the function of the energy control program, and the safe application, usage and removal of energy controls for hazardous energy sources. Employee(s) were exposed to amputation and crushing hazardous while performing servicing and maintenance on the Saspi 501 machine. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (4)
- — P (S) $9375
- — P (S) $9375
- — I (S) $9375
1910.147 D
- Issued
- Mar 17, 2023
- Abate by
- Apr 29, 2024
- Penalty
- Initial $15,625 · Current $9,375 Reduced
General-duty citation text
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: On or about November 3, 2022, employee(s) performing servicing and maintenance tasks such as set-up were exposed to bodily injury and crushing hazards due to unexpected start-up. Employee(s) were not required to control hazardous energy sources in the following sequence. (1) prepare for shutdown, (2) shut down machine or equipment, (3) physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the energy source, (4) affix lockout or tagout devices to each energy isolating device by authorized employee, (5) relieve, disconnect, restrain or otherwise render safe all stored or residual energy, (6) verify that isolation and deenergization of the machine or equipment have been accomplished: Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (4)
- — P (S) $9375
- — P (S) $9375
- — I (S) $9375
More inspections at Semblex Corporation
View Semblex Corporation's full OSHA safety record →
More inspections in this industry (NAICS 336390)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346337934.