OSHA Inspection: BRONZ-GLOW TECHNOLOGIES, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of BRONZ-GLOW TECHNOLOGIES, INC. in 1850 WAMBOLT STREET, JACKSONVILLE, FL 32202 (NAICS 332812). OSHA activity number 346343734.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bronz-Glow Technologies, INC. — free Get an email when a new federal OSHA severe-injury report for Bronz-Glow Technologies, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1850 WAMBOLT STREET
City
JACKSONVILLE
State
FL
ZIP
32202
Mailing
175 BRONZ GLOW WAY, SAINT AUGUSTINE, FL 32095
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
7
Ownership type
A

4 citations on file for this inspection.

1910.1000 B02

Serious Gravity 10 1 instance 2 exposed
Issued
May 8, 2023
Abate by
Aug 18, 2023
Penalty
Initial $6,250 · Current $4,000 Reduced

Hazardous substances 2460

29 CFR  1910.1000(b)(2): Employee(s) were exposed to an airborne concentration of Toluene listed in Table Z-2 in excess of the ceiling concentration of 500ppm (Peak):  a.	Paint Area: On or about November 16, 2022 and at times prior, an employee was exposed to airborne concentrations of Toluene in excess of the peak value. The sampling was performed for 169 minutes.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $6250

1910.134 E01

Serious Gravity 10 1 instance 2 exposed
Issued
May 8, 2023
Abate by
Jul 14, 2023
Penalty
Initial $0 · Current $0

Hazardous substances 2460

29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was fit tested or required to use the respirator in the workplace:   a)  Paint Area;  On or about November 16, 2022, and at times prior, the employer exposed employees to potential respiratory hazards in that employees were required to wear a tight fitting half face negative pressure respirator without first being medically evaluated to ensure the employees are medically able to wear a negative pressure respirator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Serious Gravity 10 1 instance 2 exposed
Issued
May 8, 2023
Abate by
Jul 14, 2023
Penalty
Initial $0 · Current $0

Hazardous substances 2460

29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):   a)  Paint Area;  On or about November 16, 2022 and at times prior, the employer exposed employees to potential respiratory hazards in that employees were required to wear tight fitting half face negative pressure respirators without first being fit tested.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 G01 I A

Serious Gravity 10 1 instance 1 exposed
Issued
May 8, 2023
Abate by
Jul 14, 2023
Penalty
Initial $0 · Current $0

Hazardous substances 2460

29 CFR 1910.134(g)(1)(i): The employer did not prohibit respirators with tight-fitting facepieces to be worn by employees who had facial hair that came between the sealing surface of the facepiece and the face:  a)  Paint Area;  On or about November 16, 2022 and at times prior, the employer exposed an employee to potential respiratory hazards in that an employee was allowed to have facial hair that came between the sealing surface of the respirator facepiece and his face resulting in inadequate seal.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0