Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NATIONAL PARK SERVICE, REDWOOD NATIONAL AND STATE PARKS, NORTH DISTRICT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NATIONAL PARK SERVICE, REDWOOD NATIONAL AND STATE PARKS, NORTH DISTRICT in 500 AUBELL LANE, CRESCENT CITY, CA 95531 (NAICS 712190). OSHA activity number 346343866.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Park Service, Redwood National and State Parks, North District — free Get an email when a new federal OSHA severe-injury report for National Park Service, Redwood National and State Parks, North District is published. One employer, no account, unsubscribe in one click.
Site address
500 AUBELL LANE
City
CRESCENT CITY
State
CA
ZIP
95531
Mailing
1111 SECOND STREET, CRESCENT CITY, CA 95531
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
25
Ownership type
D

8 citations on file for this inspection.

1910.303 G01

Serious Gravity 5 2 instances 3 exposed
Issued
Dec 2, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1):Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment. Occurrences of this violation are detailed below.   1). Located at the North Operations Center (NOC) of Redwood National Park, in the upstairs storage area of the vehicle bay (room 130), a PV Powered brand 600-VDC photovoltaic inverter, S/N *PV0300BACA0310090143*, was obstructed by a pallet of equipment from the road crew.  2). Located in the electrical mechanical room (room 116) of the NOC,  a General Electric heavy duty safety switch was obstructed by HVAC air filters.   Employees are exposed to an electrical hazard that could result in smoke inhalation or burns.
Recent events (1)
  • — Z (S) $0

1910.157 E03

Other-than-serious 1 instance 1 exposed
Issued
Dec 2, 2022
Abate by
Jan 23, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(3):Portable fire extinguishers were not subjected to an annual maintenance check. Located in the Vehicle Bay Room 130 of the North Operations Center, one fire extinguisher did not have an up-to-date annual inspection tag. A fire extinguisher was located next to an exit door on the floor with the most recent inspection marking indicating it was last inspected in 2016. Employees are exposed to a fire hazard that could result in burns or smoke inhalation.
Recent events (1)
  • — Z (O) $0

1910.253 B04 III

Serious Gravity 5 2 instances 1 exposed
Issued
Dec 2, 2022
Abate by
Jan 23, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire resistant rating of at least one-half hour.   1). Located in the Vehicle Bay (room 130) in the truck bed of the industrial truck equipped with the Venturo crane (NPS #NP8000130125), an oxygen cylinder was stored next to an acetylene cylinder in the front of the truck on the right hand side.
Recent events (1)
  • — Z (S) $0

1910.184 I09 III

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 2, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.184(i)(9)(iii):Synthetic web sling(s) with snags, punctures, tears or cuts were not immediately removed from service. Located in the vehicle bay, room 130, of the North Operations Center, there was an Acme Rigging brand synthetic web sling with snags and tears hanging on the wall available for use near other rigging materials. Employees are exposed to a crush hazard.
Recent events (1)
  • — Z (S) $0

1910.184 I01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 2, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.184(i)(1):Synthetic web sling(s) were not marked or coded to show rated capacities for each type of hitch and type of synthetic web material. Located in the North Operations Center, Vehicle Bay (Room 130), a synthetic web sling did not have rated capacities displayed. The manufacturer labeling was worn off and unreadable. Employees are exposed to a crush hazard.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 2 instances 3 exposed
Issued
Dec 2, 2022
Abate by
Feb 6, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.   1). Located in the Vehicle Bay, Room 130, a Sunex-HD 20 Ton Air/Hydraulic Shop Press, Model 5720AH, did not have a guard at the point of operation.  2). Located in the Electrical and Water Utilities room, a Ryobi DP121L drill press did not have a machine guard at the point of operation.   Employees are exposed to machine hazards that  could result in amputation, broken bones, or injuries from flying objects.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 2, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2):Listed or�labeled electrical�equipment was�not used�or installed�in accordance�with instructions�included in�the listing�or labeling. Located in the employee break room, one microwave was plugged into a relocatable power tap. Employees are exposed to an electric shock hazard.
Recent events (1)
  • — Z (S) $0

1910.305 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 2, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in wet locations were not weatherproof. Located on the exterior of the shared storage building at the NOC, an electrical outlet was not covered by a weatherproof enclosure. Employees are exposed to an electric shock hazard.
Recent events (1)
  • — Z (S) $0

View National Park Service, Redwood National and State Parks, North District's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346343866.