Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STARK'S METAL WORKS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of STARK'S METAL WORKS, INC. in 815 HOFLAND ROAD, MENOMONIE, WI 54751 (NAICS 332999). OSHA activity number 346346844.

Watch Stark'S Metal Works, INC. — free Get an email when a new federal OSHA severe-injury report for Stark'S Metal Works, INC. is published. One employer, no account, unsubscribe in one click.
Site address
815 HOFLAND ROAD
City
MENOMONIE
State
WI
ZIP
54751
Mailing
815 HOFLAND ROAD, MENOMONIE, WI 54751
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
19
Ownership type
A

11 citations on file for this inspection.

1910.107 C02

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3572.00 · Current $2143.00 Reduced
29 CFR 1910.107(c)(2): Open flame or spark producing equipment was not kept from a spraying area nor within 20 feet, unless separated from by a partition:  (a) Spray finishing area; Arc welding operations were conducted within 20-feet of a spray booth where deposits of combustible residues were present.
Recent events (2)
  • — I (S) $2143.2
  • — Z (S) $3572

1910.107 C05

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.107(c)(5): Electrical equipment in spraying areas, where deposits of combustible residues were readily accumulated, were not approved for the location:  (a) Spray finishing area; A 30-inch drum fan operated inside a spray booth and subject to deposits of combustible residues, was not approved for use in that location.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 G02

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary:  (a) Spray finishing area; Housekeeping was not maintained as necessary to keep floors and surfaces of the paint booth clear of deposits of combustible residues.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 G07

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.107(g)(7): "No smoking" signs in large letters on contrasting color background were not posted at all spraying areas and paint storage rooms:  (a) Spraying area; A "No Smoking Sign" was not posted at or in the vicinity of a spray booth in which paints having combustible or flammable properties were used and/or stored.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3572.00 · Current $2143.00 Reduced
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:  (a) Welding area; The employer did not ensure that employee(s) who wore respirators, other than filtering facepieces, on a voluntary basis, were medically evaluated and determined physically able to wear respirators.
Recent events (2)
  • — I (S) $2143.2
  • — Z (S) $3572

1910.212 A03 II

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $5358.00 · Current $3215.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  (a) Composite/wood cutting area; The lower periphery of the blade on a Cobalt brand model no. 1413794 10-inch compound miter saw was not guarded.   (b) Composite/wood cutting area; The exposed portion of the blade on a Dewalt brand model no. DW 745 10-inch table saw was not guarded.
Recent events (2)
  • — I (S) $3214.8
  • — Z (S) $5358

1910.303 G02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3572.00 · Current $2143.00 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  (a) Composite/wood cutting area; An electrical switch used to control power for a Dewalt brand model no. DW 745 10-inch table saw was missing a front cover, exposing energized conductors.
Recent events (2)
  • — I (S) $2143.2
  • — Z (S) $3572

1910.305 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3572.00 · Current $2143.00 Reduced
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed:  (a)  North shop bay; An energized electrical breaker panel located on the wall behind the press brake was missing a circuit breaker blank.
Recent events (2)
  • — I (S) $2143.2
  • — Z (S) $3572

1910.1200 E01

Serious Gravity 1 1 instance 19 exposed
Issued
Abate by
Penalty
Initial $2678.00 · Current $1607.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  (a) Throughout the facility; A written hazard communication program was not implemented for chemicals such as, but not limited to, oil and water-based paints, paint thinner, degreasers, and gas metal arc welding operations.
Recent events (2)
  • — I (S) $1606.8
  • — Z (S) $2678

1910.134 K06

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  (a) Welding and painting areas; The employer did not ensure that employee(s) were provided information contained in Appendix D of 29 CFR 1910.134 prior to voluntary respirator use.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 L06

Other-than-serious 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):   (a) Throughout the facility; The employer did not complete powered industrial truck training in accordance with paragraph (l) requirements as the training did not include an evaluation and/or certification of the operator's performance.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346346844.