BEAUFORT, SC —
OSHA Inspection: SAGA PROFESSIONAL SERVICES, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SAGA PROFESSIONAL SERVICES, LLC in BUILDING 729, BEAUFORT, SC 29906 (NAICS 238990). OSHA activity number 346351299.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAGA PROFESSIONAL SERVICES, LLC
- Site address
- BUILDING 729
- City
- BEAUFORT
- State
- SC
- ZIP
- 29906
- Mailing
- 49 LANDON LANE, BEAUFORT, SC 29906
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.102 A01
- Issued
- Jan 13, 2023
- Abate by
- Feb 6, 2023
- Penalty
- Initial $2,486 · Current $1,492 Reduced
General-duty citation text
29 CFR 1926.102(a)(1):The employer did not ensure that each affected employee use appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a) Outside building 729, on or about November 17, 2022, the employer did not ensure that an employee who was pressure washing an aerial lift wore eye protection, resulting in a struck-by hazard
Recent events (2)
- — I (S) $1491.6
- — Z (S) $2486
1926.405 B02
- Issued
- Jan 13, 2023
- Penalty
- Initial $1,865 · Current $1,119 Reduced
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: a) Throughout building 729, on or about November 17, 2022, faceplates and/or covers were not installed on energized outlet boxes, resulting in an electrical hazard.
Recent events (2)
- — I (S) $1119
- — Z (S) $1865
1910.134 K06
- Issued
- Jan 13, 2023
- Abate by
- Feb 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6):The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: (Construction Reference 1926.103) a) At building 729, on or about November 17, 2022, the employer did not provide the information contained in Appendix D to an employee who used a filtering facepiece respirator on a voluntary basis while sanding.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238990)
More inspections in SC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346351299.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.