Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: D&U METAL ROOFING, INC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of D&U METAL ROOFING, INC in 438 OLD BEDFORD ROAD, CONCORD, MA 01742 (NAICS 238160). OSHA activity number 346351448.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D&U Metal Roofing, INC — free Get an email when a new federal OSHA severe-injury report for D&U Metal Roofing, INC is published. One employer, no account, unsubscribe in one click.
Site address
438 OLD BEDFORD ROAD
City
CONCORD
State
MA
ZIP
01742
Mailing
30 CORNELL STREET APT 2, LOWELL, MA 01851
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
1
Ownership type
A

1 citation on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 7, 2023
Penalty
Initial $4,219 · Current $4,219
29 CFR  1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s).  Location: 438 Old Bedford Road, Concord, MA;  On or about 11/18/22, employees were exposed to the following hazardous conditions as a result of the controlling employer not conducting frequent and regular inspections of the jobsite:  Instance a) Employees exposed to a falls greater than 6-feet while installing metal roofing without a means of fall protection. Instance b) Extension ladders were not positioned to provide three feet of extended clearance for access and egress to the roof's edge from the ladder. Instance c) A ladder jack scaffolding platform was constructed in a manner which created a cantilevered section at one end which extended greater than 18-inches beyond the platform's support. Instance d) A crawling board (Chicken Ladder) did not extend from the roof peak to the eaves when used in connection with roof construction, repair, or maintenance.
Recent events (1)
  • — Z (S) $4219

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346351448.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.