OSHA Inspection: MOREHOUSE INSTRUMENT COMPANY, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of MOREHOUSE INSTRUMENT COMPANY, INC. in 1742 6TH AVENUE, YORK, PA 17403 (NAICS 339999). OSHA activity number 346363716.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Morehouse Instrument Company, INC. — free Get an email when a new federal OSHA severe-injury report for Morehouse Instrument Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1742 6TH AVENUE
City
YORK
State
PA
ZIP
17403
Mailing
1742 6TH AVENUE, YORK, PA 17403
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339999
Employees
30
Ownership type
A

3 citations on file for this inspection.

1910.107 A05 III

Serious Gravity 5 1 instance 1 exposed
Issued
May 2, 2023
Penalty
Initial $7,813 · Current $4,500 Reduced
29 CFR  1910.107(a)(5)(iii):overspray dry filters to minimize dusts or residues entering exhaust ducts;   a) Paint booth area - The employer did not install filters to minimize dusts or residue to enter the exhaust system, on or about November 30, 2022.  No abatement certification or documentation required.
Recent events (3)
  • — F (S) $4500
  • — C (S) $7813
  • — Z (S) $7813

1910.107 C06

Serious Gravity 5 1 instance 1 exposed
Issued
May 2, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for  Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:  a) Paint booth - An extension cord, located within the confines of the paint booth, was not designed for use in a Class I, Division 1, Hazardous Location, on or about November 30, 2022.  No abatement certification required.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.107 C08

Serious Gravity 5 1 instance 1 exposed
Issued
May 2, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.107(c)(8): Portable lamp(s) used in spraying area(s) during cleaning or repairing operations were not of the type approved for hazardous Class I locations:  a) Paint booth - The employer had placed a work lamp within the area of the paint booth that was not  electrically rated for Class 1 locations, on or about November 30, 2022.  No abatement certification required.