YORK, PA —
OSHA Inspection: MOREHOUSE INSTRUMENT COMPANY, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of MOREHOUSE INSTRUMENT COMPANY, INC. in 1742 6TH AVENUE, YORK, PA 17403 (NAICS 339999). OSHA activity number 346363716.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MOREHOUSE INSTRUMENT COMPANY, INC.
- Site address
- 1742 6TH AVENUE
- City
- YORK
- State
- PA
- ZIP
- 17403
- Mailing
- 1742 6TH AVENUE, YORK, PA 17403
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339999
- Employees
- 30
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.107 A05 III
- Issued
- May 2, 2023
- Penalty
- Initial $7,813 · Current $4,500 Reduced
General-duty citation text
29 CFR 1910.107(a)(5)(iii):overspray dry filters to minimize dusts or residues entering exhaust ducts; a) Paint booth area - The employer did not install filters to minimize dusts or residue to enter the exhaust system, on or about November 30, 2022. No abatement certification or documentation required.
Recent events (3)
- — F (S) $4500
- — C (S) $7813
- — Z (S) $7813
1910.107 C06
- Issued
- May 2, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: a) Paint booth - An extension cord, located within the confines of the paint booth, was not designed for use in a Class I, Division 1, Hazardous Location, on or about November 30, 2022. No abatement certification required.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.107 C08
- Issued
- May 2, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(c)(8): Portable lamp(s) used in spraying area(s) during cleaning or repairing operations were not of the type approved for hazardous Class I locations: a) Paint booth - The employer had placed a work lamp within the area of the paint booth that was not electrically rated for Class 1 locations, on or about November 30, 2022. No abatement certification required.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 339999)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346363716.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.