Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NOURIA ENERGY RETAIL, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NOURIA ENERGY RETAIL, INC. in GOLDEN NOZZLE CAR WASH 22 SOUTH STREET, WEST HARTFORD, CT 06110 (NAICS 811192). OSHA activity number 346364243.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nouria Energy Retail, INC. — free Get an email when a new federal OSHA severe-injury report for Nouria Energy Retail, INC. is published. One employer, no account, unsubscribe in one click.
Site address
GOLDEN NOZZLE CAR WASH 22 SOUTH STREET
City
WEST HARTFORD
State
CT
ZIP
06110
Mailing
326 CLARK STREET, WORCESTER, MA 01606
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811192
Employees
4
Ownership type
A

3 citations on file for this inspection.

1910.22 A03

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 17, 2023
Penalty
Initial $5,692 · Current $3,984 Reduced
29 CFR  1910.22(a)(3): The employer did not ensure that walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice.  On or about November 30, 2022, employees at the 22 South Street, West Hartford, CT,  golden nozzle carwash were exposed to a protruding metal grate in the car wash tunnel while performing tasks such as, but not limited to, pit and track cleaning activities.
Recent events (2)
  • — I (S) $3984.4
  • — Z (S) $5692

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 17, 2023
Penalty
Initial $5,692 · Current $3,984 Reduced
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  Electrical maintenance area: On, or about, November 30, 2022, the small desk fan attached to the wall was energized through an orange extension cord to cool off the following equipment:  A. Franklin Electric Cerus Industrial Titan P Series variable frequency drive.
Recent events (2)
  • — I (S) $3984.4
  • — Z (S) $5692

1910.147 C06 I

Other-than-serious 1 instance 2 exposed
Issued
Mar 17, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  On or about Novemebr 30, 2022,  the energy control procedure for the periodic inspection for lockout and tagout had not been done at least annually.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Nouria Energy Retail, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346364243.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.